Level Alarm

CPX Part No.
606171, 10 m cable
606181, Wireless with batteries.
Mount the level sensor (1) with supplied M8
screw, washer and nut at the edge of the tank as shown in
the picture. First drill an 8 mm hole approximately 90
degrees away from the Inlet pipe.
The alarm will be triggered when fluid reaches both contact
surfaces located in the far end of the dipstick.
If desired the hose clamp can be moved from the set position
to trigger the alarm sooner or later.
For Part No 606181: Place the wireless sender as high as possible and attach with supplied
screw.
For Part No 606171: Drill a 16 mm hole for the rubber grommet. Deburr the hole! With an e.g.
awl make a small hole in center of the grommet and then pull through the cable.
______________________________________________________________
Management
The tank, equipment and accessories must be handled with care. Do not allow these parts to
come into contact with objects that may cause damage. On receiving delivery and prior to
installation, inspect the products carefully for any signs of damage.
Lifting the tank
The tank is to be lifted using soft bands that
can be threaded through the four inbuilt lifting
holes. The tank will then be well balanced
during lifting operation.
The tank must be empty when lifted.
11