ARCA ArcaCash 2600 Рабочая инструкция - Страница 4

Просмотреть онлайн или скачать pdf Рабочая инструкция для Диспенсер ARCA ArcaCash 2600. ARCA ArcaCash 2600 7 страниц. Front to rear dispense conversion

6. Reassemble lower hinge blocks to the rear left side of safe with pins extended toward the rear of the
safe.
7. Reinstall cosmetic door with hinge pins and washers.
8. Adjust hinge mounting screws as needed to ensure that the cosmetic door keylatch properly engages the
latching features in rear wall of safe. Note: Straighten keylock latch if bent.
9. Reinstall screw caps.
2.2
Remove and Reassemble the Shutter Assem
10. Disconnect shutter cable by unplugging the black 10-position (2x5) Hirose-style connector.
11. Remove shutter assembly from the front door of the safe by removing (4) mounting screws. Retain
screws and white plastic cable holder for reuse later.
12. Reinstall shutter to outside rear wall of safe using the (3) same-length mounting screws in both top
positions and the lower left position. Do not stall the longer (4
be installed later when cabling is routed through rear safe wall and reconnected to shutter assembly.
2.3 Remove the Dispenser
13. Release dispenser tray and pull outward. Tray will extend on ball-bearing slides. Note: There are holes in
the left side ball-bearing slide (near the safe) to push a screwdriver through to hold the tray in the
extended position.
14. Take note of how cables are routed and connected as they exit the cable carrier chain and connect to the
dispenser.
15. Disconnect all cabling that exits the chain and connects to the dispenser. Unsnap gray clips that hold
these cables to the dispenser adjacent to the chain and clip cable ties only as necessary. Discard clipped
cable ties.
16. Remove front (2) screws retaining dispenser to bottom of tray. Retain screws for reuse later.
17. Slide dispenser forward enough on tray to disengage rear dispenser mounts.
18. Remove dispenser and set on floor. WARNING: Dispenser is heavy and awkward. It is recommended
that two people perform this step.
19. Move rear (2) screws and (2) shoulder washers forward to next set of holes marked 'RA' (approximately
2") and tighten. Note: The dispenser mounting holes in the tray are marked 'FA' for front dispensing
position and 'RA' for rear dispenser mounting position.
2.4 Reconfigure the Safe
20. Remove blanking plate from upper inside rear wall of the safe by removing (4) screws. Retain screws for
reuse in next step.
21. Reassemble blanking plate to rear surface of safe door with protrusion filling the presenter slot.
22. Remove black plastic cable clamp from inside of safe door by removing (1) mounting screw. Discard
screw and cable clamp.
23. Cut and remove cable ties that bind the shutter and dispense indicator light cables together. Discard
clipped cable ties.
24. Remove shutter and dispense indicator light cables from hole through safe door.
25. Remove (3) screws that attach upper right cable trough to top of safe. Retain screws for reuse later.
26. Only loosen (3) screws that attach upper right cable trough to right side of safe. Leaving a gap only large
enough between the cable trough and the top of the safe to pull cables through the trough.
27. Remove power switch plate mounted into end of upper right cable trough by removing (2) screws. Retain
screws for reuse later. Pull switch and plate forward out of the cable trough but do not remove power
switch or disconnect power wiring.
28. Remove the horizontal cable channel cover from the rear wall of the safe by removing (3) screws. Retain
cable channel cover and screws for reuse later.
File - 000010
Printed copies of this electronically controlled document are valid only for the day in which it is printed
Work Instruction
bly
th
) screw or plastic cable holder. These will
Page 2
10/11/2006 1:53:00 PM