F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
⁄ Spout temperature does not corre-
spond with temperature set
⁄ Temperature regulation not possible
⁄ Safety stop button not operating
C A U S E
⁄ Supply pressure inadequate
⁄ Filters are dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ Spring defective
⁄ Button calcified
0 5
R E M E D Y
⁄ Check water pressure (If a pump has
been installed check to see if the
pump is working).
⁄ Clean filter in front of the mixer and on
the MTC-thermo cartridge
⁄ Clean filter seal between shower and
hose
⁄ Clean backflow preventers, exchange
if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to
42 ºC to 65 ºC
⁄ Exchange thermo cartridge
⁄ Clean spring and ⁄or button, exchange
if necessary