CIPU CSPPD705 Руководство - Страница 10

Просмотреть онлайн или скачать pdf Руководство для Насос для плавательного бассейна CIPU CSPPD705. CIPU CSPPD705 13 страниц.

CIPU CSPPD705 Руководство

TROUBLESHOOTING

Problem
Cause
Low flow
Dirty filter
Dirty skimmer and pump
strainer
Suction air leak
Closed valve or blocked line
Pump does
Not plugged in
not run
GFCI/or main circuit breaker
tripped
Faulty Pump shaft /motor
Pump shaft is locked
Pump will
Suction air leak
not prime
No water in the pump
Closed valves or blocked
lines
Motor
Motor not connected properly
overload
Low incoming voltage
cuts out
Overload due to binding in
pump or wrong size impeller
Noise pump
Bad bearing
Solution
Backwash or clean cartridge
Clean skimmer and pump strainer
Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal
Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal
Check the socket and power cord
Switch on the breaker. If it is immediately
tripped again,
There is a defect in pump or controls.
Replace the pump/motor assembly.
Check if the pump can be rotated by hand
and remove any blockage
Make sure water level is correct through
suction points. Ensure baskets and
strainers are free of debris. Tighten all
fittings/unions on the suction side of the
pump, remove and replace mechanical
seal
Make sure the filter tank is full
Open all valves in the system, clean
skimmer and pump basket, check pump
impeller of blockage
Have electrician check wiring
Voltage at motors should be no more than
6% above or below nameplate voltage.
Have electrician check voltage; ensure
pump is not running on an extension cord.
Report low supplier to authorities.
Contact supplier
Have electrician replace
9