Digicode DGA Руководство по установке - Страница 8
Просмотреть онлайн или скачать pdf Руководство по установке для Клавиатура Digicode DGA. Digicode DGA 20 страниц. Surface-mount keypad - cast aluminium
INSTALLATION MANUAL
DGA
Cast aluminium Digicode
3]
WIRING DIAGRAM
INPUT VOLTAGE
230 V
12V à 24VAC
12V à 48VDC
INPUT VOLTAGE
230 V
Locking devices
Wires
Black
Input voltage 12V or 24V AC or DC
Red
Input voltage 12V or 24V AC or DC
Brown
Relay 1 N/C contact
Pink
Relais 1 common
Orange
Relay 1 N/O contact
Yellow
Common
Dark Green
Relay 1 request-to-exit input
Light Green
H Timer input
Blue
User code modification
Dark Blue
Relay 2 N/C contact
Purple
Relais 2 common
Gray
Relay 2 N/O contact
White
Reset
cdvi.se
8
cdvigroup.com
Self Contained
®
Pink [C1]
ELECTROMAGNET
Brown [NC]
Orange [NO]
V
Yellow
Dark green
P1
Light green
H
Purple [C2]
STRIKE
Gray [NO]
Dark blue [NC]
V
RESET
Description
Black
Red
Blue
White
V
Varistor
This device comes with a
varistor. The varistor must
be connected on the strike
terminal
operated by the device. If
this product operates more
than one strike, each lock
should have a varistor. The
varistor controls the overload
produced by the strike coil –
back emf.
EN
(electromagnet...)