Axxeron HESCH HE 5710 Руководство по эксплуатации - Страница 12

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Контроллер Axxeron HESCH HE 5710. Axxeron HESCH HE 5710 19 страниц. Solenoid valve controller

3.3

Technical Data

Technical Data
Intended use:
Supply voltage:
Power consumption:
LED:
Inputs:
Valve outputs:
Valve voltage:
Valve current:
Fuse:
Electrical connections:
Operating temperature:
Designs:
Connection set (option):
Subject to technical changes.
12
-solenoid valve controller for cleaning industrial filtration plants
-100...240 V AC, 50...60 Hz
-24 V DC ± 10% (option) (safety extra-low voltage SELV)
30 VA, self-consumption about 3 kW
- HE 5710: 4 for valve control, red
- HE 5711: 8 for valve control, red
-RUN, green
-PULSE, yellow
-TEST, green
-START: start cleaning (contact closed)
-START CYCLE: cycle cleaning (trigger signal), switchable with a
potential-free contact or semiconductor switch, "Active Low"
- HE 5710: 1...4
- HE 5711: 1...8
24 V DC ± 10%
-1 A for a pulse time ≤ 1s and a pause time ≥ the pulse time
-The outputs are short-circuit-proof
Glass fuse 5 × 20 mm, 2 A, slow-bow
Vertical cage spring release terminals
-20°C...+50°C
-20°C...+40°C in EX zone
- Assembly on standard rail support: 165 mm × 111 mm (W × H)
-dust-proof Makrolon housing (IP65) with transparent cover, with a
M25 × 1.5 thread and two M32 × 1.5 threads for metric screw
connections
-If necessary, openings should be closed with screw plugs, to
make the device dust-proof (IP65)
-An M32 screw plug is in the scope of delivery of HE 5710
Housing dimensions: 180 mm × 130 mm × 78 mm (W × H × D)
-1 × M25 screwed cable gland
-2 × M32 screwed cable gland
-Multiple sealing inserts and locking bolts
-Height of the cable gland: 40 mm
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4