Creda Aquawave White Руководство по установке и эксплуатации - Страница 5

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Сантехническая продукция Creda Aquawave White. Creda Aquawave White 8 страниц. Electric shower (covers white, colour and heritage models)

Creda Aquawave White Руководство по установке и эксплуатации
WHAT TO DO IF THINGS GO WRONG (2)
PROFESSIONAL SERVICE
If the previous "Self Help" checks fail to restore the performance, you should seek professional help.
The person who installed the shower is probably the best one to investigate and correct it and is
certainly the person to contact if you have had a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified service person.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Water too HOT
Water flow restricted by blockage in filter of solenoid valve.
Replace the solenoid valve.
Water too COLD
Check circuit through thermal cut-out.
Check circuit through microswitches on the pressure switch & power selector.
Check each element circuit (and phased shut-down relay on 10.5kW model).
Check tightness of electrical connections.
No control over
Check control knob is correctly engaged onto the stabiliser valve drive gear.
water flow
Undo headworks of stabiliser valve.
Check stabiliser is in place and remove any debris in valve then re-assemble.
Water discharges
Check for cause of high pressure and remove it.
from pressure
Blockage on outlet e.g. blocked shower handset.
relief valve
Replace the pressure relief disc (not covered by guarantee).
Water does not
Check circuit through solenoid coil (and timer PCB on 10.5kW model).
flow when button
Check circuit through push button switch. If items are defective then replace.
"B" is pressed.
Power supply not reaching shower.
CREDA AFTER SALES SERVICE
We offer a technical advisory service on the telephone to installers and other customers with
problems in the field.
RING 0870 9000 430 (UK ONLY)
Remember to quote the exact type of shower, as written on the shower front and on is leaflet.
The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.
Model Number: 53-67_ _ _ _ _ _ _ / Serial Number: _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.
12

COLD WATER INLET PIPE CONFIGURATION

Please note that standard compression fittings are shown.
Push-Fit connections or a combination of the two are also suitable.
To aid installation, you may find it convenient to move the flexible pressure relief valve outlet
assembly by removing the two securing screws.
If you do, please ensure that they are fully tightened on re-assembly (see Diagram 2b).
5