LOADING DEFAULT LISTS (Only in CLP Board)
CLP board allows you to change all values. Beside this, you can load default lists at any time. Default
lists are adjusted as such that -1, 0, 1, 2..... or 0, 1, 2, 3 from floor 0 to top floor. You can load all these
values at one step.
When you set Floor 0 to a value such as -2 and if you save it by holding ENT, DEC (↓) and INC (↑)
buttons all, then the next floors automatically set to -1,0,1...
RUN MODE
Push and hold INC (↑) and DEC (↓) button to enter run mode settings. In this menu system allows you
to set
Floor Selector
Board ID (Only in CLC/CLT)
Floor Number
Sliding Displays
FLOOR SELECTOR
CLP board can be driven by 7 Segment, Gray Code, Binary Code or Counter systems inputs. CLC and
CLT boards only can be driven by CANBus. Additional to floor selectors, simulation mode can be set
to simulate system work.
RM letters on display shows Run Mode. Submenus of this mode are
BN:
Binary Code
GR:
Gray Code
7S:
7 Segment
CN:
Counter
CB:
CANBus
SM:
Simulation
ID DEFINITION
(Only in CLC and Board)
ID information (0 to 63) of CLC and CLT boards must be set to identify address of it in CANBus
communication. ID letters on display shows this menu.
FLOOR COUNT DEFINITION
Floor count at simulation mode can be set in this menu. SF letters on display shows this menu.
SLIDE DISPLAY SETTINGS
Set this menu to 1 for floor information and arrow set as a slide type at changes. SL letters on display
shows this menu.
F/7.5.5.02.87 R:2
4