OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120-PH and 121-PH Series Proof/Hot Cabinets
CAUTION
WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.
TROUBLE-SHOOTING CHART:
FAILURE
1. Yellow light does NOT light.
2. Red light does NOT light.
3. Unit does not get hot.
4. Unit gets too hot or won't shut off.
5. Humidity is low
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Instructions for replacing parts are included with the replacement parts kits.
REPLACEMENT PARTS:
Description
Proof/Hot Unit ...........................................PHU-18-747-18 .................... PHU-18-747-19
Water Pan w/Heater
Water Pan Cover
Heater (Water Pan) 1000W
Heater (Water Pan) 900W ......................................................................... 0811-015K
Heater
(Tunnel)..........................................0811-075
Latch, Door
................................................1136-K
Power Cord Kit
Power Light (Yellow)
Power Light (Red)
Relay
..........................................................0857-097
Switch Kit
..................................................0808-082
Strain Relief Collar ....................................5459-004-03 ..........................
Terminal Block
Thermostat Kit
Thermometer Kit
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
DELIME OR DESCALE RESERVOIR PARTS AS REQUIRED
TO PREVENT DAMAGING BUILD-UP.
...................................0756-014
........................................1245-001
........................0811-005-K
..........................................0810-093
................................0766-048
.....................................0766-047
..........................................0978-007-K
...........................................0848-062-K
.......................................5238-018-K
POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet or cabinet.
1c. Switch is "OFF".
2a. Thermostat turned "OFF".
2b. Thermostat set too low (light comes on when
heater is on).
3a. Thermostat set too low or is "OFF".
3b. Water in pan my be low.
3c. Switch is "OFF".
4a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
5a. Water in pan may be low
5b. Thermostat set too low
120 Volt
............................... 0756-015
...............................
............................... 0811-078
..................................
...............................
...............................
...............................
...............................
............................... 0808-010
...........................
...........................
...........................
Proof/Hot
FL-0604
Cabinets
Rev. 20 (3/10)
Page 3 of 4
240 Volt
1245-001
1136-K
0810-039
0766-045
0766-046
0857-098
5459-004-1
0978-007-K
0848-062-K
5238-018-K