Transducer assembling
The magnetic transducer measures the movement of the magnet which rotates on the revolving part:
every time that the magnet pass by the transducer it creates an impulse which will be worked out of the
instrument to visualize the required parameters.
The correct assembling of the transducer provides that the magnet is mounted on the shaft that turns
with the coil on which is wound the tube.
This is very important for the functioning of reading system because the display has to measure the
drawn out meters during the unwinding of tube.
Do not mount the transducer on a shaft in neutral during the unwinding of tube.
CABLE SIDE VIEW
NO
YES
MAGNET TRAJECTORY
The assembling has be carried out according to the following scheme:
The transducer has on the cable side a small nick that comes out from the resin tapping; this reference
has to be in line to the flight that covers the magnet when it is rotating in front of the transducer.
During the irrigation the minimum speed perceivable from the display is 1 impulse every 100 seconds,
therefore the minimum rotation speed of the shaft on which is mounted the transducer, must be higher
then 0,6 rpm (1 revolution each 100 seconds).
As indication has to be considered that the instrument updates the reading every time the magnet
passes in front of the transducer, therefore to have a faster update of the display it's advisable to
assemble the transducer on a shaft which during the irrigation has a not too slow speed (for ex. with 5
rpm it reaches a reading update each 12 seconds).
As higher speed limit has to be considered that the maximum rotation speed happens during the drawn
out of tube and this do not have to exceed 2000 rpm.
Transducer connection
To connect the transducer open the back panel of the instrument screw off the 4 closing screws, reach
the 3 poles terminal board taking out the battery case. Thread the cable into the press-cable and
connect it according to the following scheme:
1
BROWN
2
BLACK
3
BLUE
Carried out the connection close the panel and shut the press-cable. Once mounted and connected the
transducer on the irrigator, if the direction is not the same of the instrument, its enough to change
round the connection of the blue and black wire on the terminal board inside the instrument or turn the
transducer half a round to move the reference nick of 180 degrees.
N.B.: if the machine direction is not the same of the instrument during the tube drawing, after the zero
setting of the display, instead of the unwound meters, the display will shows an error message - - -.
Data: 20/02/06
YES
TRANSDUCER
CABLE
REFERENCE
TO CHANGE ROUND THE DIRECTION, EXCHANGE THE
BLACK WITH THE BLUE OR TURN THE TRANSDUCER
HALF A ROUND
File : VIR_SP_ing.doc
MIN 1
MAGNET TRAJECTORY
MAX 5
CH17
MAGNETIZED SIDE (SMOOTH)
Rev:1.2
MIN 0,6 RPM
MAX 2000 RPM
MAGNET
CH13
Pagina 2 di 4