Cres Cor 1000CHSKD Руководство по установке, эксплуатации и техническому обслуживанию - Страница 3
Просмотреть онлайн или скачать pdf Руководство по установке, эксплуатации и техническому обслуживанию для Курильщики Cres Cor 1000CHSKD. Cres Cor 1000CHSKD 15 страниц. Radiant smoker ovens
5925 Heisley Road • Mentor, OH 44060-1833
VENTING YOUR OVEN:
1. The purpose of ventilating hoods is to direct and
capture smoke, grease-laden vapors, heat, odors, or
fumes.
2. Low temperature equipment (maximum
temperature 250°F/121°C) does not produce heat,
odors, fumes, grease-laden vapors or smoke and is
not required to be vented.
SPECIFICATIONS: All units are rated 3000 watts/2650 watts at 208 Volts/240 Volts
CMP MODEL NOS.
SINGLE OVENS
500CHSKD
767CHSKD
1000CHSKD
500CHSKD3
767CHSKD3
1000CHSKD3
SPECIFICATIONS: All units are rated 2000 watts.
CMP MODEL NOS.
SINGLE OVENS
500CHSKD120
767CHSKD120
1000CHSKD120
All models designed for AC Service. Model number may include a variety of informational suffix letters.
NOTE: OVENS NEED TO BE INSTALLED BY A
QUALIFIED PERSON.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
INSTALLATION INSTRUCTIONS
ELECTRICAL SPECS
(AC SERVICE)
Volts
Ph
Hz.
208
1
60
240
1
60
208
3
60
240
3
60
ELECTRICAL SPECS
(AC SERVICE)
Volts
Ph
Hz.
120
1
60
3. Most jurisdictions consider our low-temperature
ovens (maximum temperature is 350°F/177°C) as
low-heat appliances not requiring vent hoods.
4. Installation must conform with local codes. The
authority having jurisdiction of enforcement of
the codes will have the responsibility for making
interpretations of the rules.
ELEC. LOAD
Amps
Volts
Amps
14
208
20
11
240
20
8
208
20
7
240
20
ELEC. LOAD
Amps
Volts
Amps
16.6
120
20
For models rated at 208/240 Volts:
Check the voltage selector switch which is under an access
cover on the back of the oven near the power cord.
Flip the switch "UP" for 208 Volts
Flip the switch "DOWN" for 240 Volts
MAKE SURE THE SWITCH POSITION MATCHES
YOUR POWER SOURCE.
Smoker Ovens
Rev. 1 (6/14)
POWER SUPPLY REQUIREMENT
Ph
Wire
Volts
1
2
208
1
2
240
3
3
208
3
3
240
POWER SUPPLY REQUIREMENT
Ph
Wire
Volts
1
2
FL-2375
Page 3 of 15
NEMA
6-20P
6-20P
L15-20P
L15-20P
NEMA
120
5-20P