8
i
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. Use
reset procedure only if
the primary controller
is missing or inopera-
ble. Certain device re-
moval can be achieved
by the procedure of
removing described in
"Adding/removing the
device" on page 6.
i
NOTE
Command Class Basic
value is related to the
status of motion sensor
(0x00 - no motion, 0xFF
- motion detected).
OPERATInG ThE DEvICE
Seismograph mode:
The Motion Sensor can be configured to work as a simple earthquake
detector, by setting the parameter 24 value to 1. Reports with scale of
the vibrations (in the Modified Mercalli Scale) will be sent immediate-
ly after vibrations have been detected. Minimal power of vibrations
that will be reported, can be set in parametr 20. Once the vibrations
cease and time of sustaining alarm elapses, reports will be stopped.
Orientation in space:
The Motion Sensor has a built-in accelerometer. When the parameter 24
is set to 2, Z-Wave network controller will be informed on the Sensor's
orientation in space by sending report after triggering tamper alarm.
Resetting the Motion Sensor:
Reset procedure erases the memory, including all information on the
Z-Wave network and the main controller.
1. Open the cover.
2. Press and hold the B-button.
3. Wait for visual indicator to glow yellow (2nd menu position).
4. Release the B-button.
5. Click the B-button to confirm selection.
6. After few seconds the device will be reset, which is signalled with
the red, fading visual indicator colour.
Notification report:
The device uses notification Command Class to report different events.
notification Type
home Security
home Security
Event
Tampering, product covering removed
Motion Detection, unknown location