Sharp SJ-47L-A2G-A2A Руководство по эксплуатации - Страница 12
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Холодильник Sharp SJ-47L-A2G-A2A. Sharp SJ-47L-A2G-A2A 32 страницы.
SJ-43L-A2
SJ-47L-A2
1. ADJUSTABLE TEMPERATURE CONTROL
(1) Temperature control of freezer
Thermostat (senses freezer temperature) operates on ON/OFF switchover to control the compressor and
cool air circulating fan , and allows the freezer temperature to keep at a suitable temperature.
However adjust the freezer temp. control knob as follows depending upon the storing condition of foods.
Figure F-1.
(2) Temperature control of refrigerator
Damper-thermostat senses temperature of the refrigerator and changes the opening angle of the damper
automatically.
However, as the Damper-thermostat has no function to switch on or off the compressor and fan motor, the
freezer temperature control causes temperature in the refrigerator to vary to some extent.
However, adjust the refrigerator temp. control knob as follows depending upon the cooling condition.
Figure F-2.
NOTE:
The refrigerator temperature is affected also by the freezer temperature. If the freezer temp.
control knob is set at the position "MAX", the temperature tends to be lower than the following
values, and if set at near the position "MIN", temperature tends to be higher.
If the refrigerator is operated for a long time with the freezer temperature control sets the "MAX"
position, foods stored in the refrigerator compartment may also freeze.
When refrigerator temperature control sets to the "Coldest", some foods stored may freeze.
In this case adjust control set back to the "MED" position.
When refrigerator temperature control sets to the "Coldest", some foods stored in Fresh case may
also become frozen.
(3) Reference value of temperature
SETTING OF
FREEZER TEMP.
CONTROL KNOB
Freezer
temperature
2 star section
temperature
The values shown above refer to the measurement carried out center area and 1/3 of overall height from the bottom
at each of the refrigerator and the freezer after machine has been operated at an ambient temperature of 30˚C with no
food stored and the door closed until the temperature is stabilized.
The values vary depending upon frequency of opening and closing the door, ambient temperature, amount of stored
foods and manner of storing foods.
FUNCTIONS
KNOB
SETTING
MAX(Coldest)
MED
MIN
2 star section
KNOB
SETTING
Coldest
MED
MIN
MAX
MED
MIN
(Coldest)
Approx.
Approx.
Approx.
-18 C
-21 C
-15 C
-15 C
-12 C
-9 C
PURPOSE
For making ice rapidly or fast freezing.
When restocking with fresh food.
For normal freezing.
For storing frozen food for a short period (up to one month).
When frozen food or ice cream is not stored.
for storing frozen food only.(not freezing)
PURPOSE
For keeping freshness of food longer.
When the refrigerator does not provide sufficient cooling.
For normal operation.
When the refrigerator provides excessive cooling.
SETTING OF
REFRIGERATOR TEMP.
CONTROL KNOB
Refrigerator
temperature
Fresh case
temperature
The values shown above refer to the case where the
freezer temp. control knob is set at "MED".
12
Coldest
MED
MIN
Approx.
Approx.
Approx.
0˚c
3˚c
6˚c
Approx.
Approx.
Approx.
-3˚c
4˚c
1˚c