3. INSTALLATION
3.1 INSTALLATION NOTICE
Only qualified service technicians/electricians should perform the installation to ensure
that all electrical and safety requirements are met and that all wiring installations are
performed in accordance with all national, state and local codes.
TOOLS REQUIRED:
Spirit Level
Phillips Screw Driver
Small Blade Straight Screw Driver
Digital Clamp Ammeter
Multimeter
Weighted Temperature Probe
Digital Temperature Meter
3.2 UNPACKING
This equipment was carefully inspected before
shipment from the factory. The transportation
company assumes full responsibility for safe
delivery to the customer until customer
acceptance of the package. Careful inspection
of the packaging and the equipment should
be completed before acceptance from the
transportation company.
3.3 XLR8 LIFTING
The equipment is heavy enough to require
additional manpower or powered assistance
when installing or moving.
When moving the equipment manually
make sure there are enough people for the task
as the equipment is heavy.
Make sure the equipment is not dropped
during moving. People doing the carrying
could be seriously injured and/or the
equipment damaged. The manufacturer does
not accept any responsibility for damage
resulted from such actions.
SP8144-2011
3.4 LOCATION AND PLACEMENT
The XLR8 electric equipment has been designed
to be mounted on an AccuTemp AccuSteam
griddle.
The operating temperature ranges from 200°-
400°F (93°- 204°C). Since these temperatures
can also be found on surfaces around the
perimeter of this commercial equipment, care
should be given not to install next to or against,
objects or surfaces with a low melting or flash
point.
3.5 CLEARANCES
Location
Back
Right Side
Left Side
Above
Arms
SUITABLE FOR ALL INSTALLATION ON COMBUSTIBLE
3.6 LEVELING
The equipment must be installed in a level
condition. An out-of-level condition will result in
an uneven compression of product and uneven
cooking.
XLR8 Installation & Operation Manual
Combustible
Non-Combustible
Construction
Construction
2 Inches
0 inches
1 Inch
0 inches
1 inch
0 inches
26 inches
26 inches (+height
(+height of
of griddle)
griddle)