Appendix C - Power Injector DUO Specifications

Injector
Power Input:
Injector
Power Output:
Output Ripple:
Output Short
Circuit Protected:
Power Reverse
Polarity Protection:
Thermal Shutdown:
Efficiency:
Port 2 Power
Injecting (PoE):
Port PoE Pins:
Startup Delay:
AC Adapter:
DC Power Cable:
Dimensions:
Remote Reset:

Appendix D - Remote Reset

A reset allows settings to be restored to a known state. For example, this can
be useful to restore username or password to default values. To perform a
Reset operation, do the following (read all instructions first):
1) The DUO will send a signal to perform a remote reset to all connected
devices. Unplug the cables of any device that you do NOT want to have
reset. Leave connected the device(s) that you wish to have reset.
2) Power on and ensure devices have had enough time to fully start.
3) Using a small screw driver or other flat ended, non sharp object, insert it
into the slot until you feel and hear a click. Note: Do not use force!
4) Hold the reset button depressed for at least 30 seconds and then release.
If the button becomes unpressed during this time, cycle the system off and
on, and wait 30 seconds before trying again. Disregard any LED patterns
12
M-POE-DUO-NS
10-20 Vdc
Input - .5V, 2A max
Capacitor
Filtering, Smoothing
Yes – internal 2A fuse
Yes – yellow LED indication
No
N/A
Yes – enabled / disabled by jumpers
Positive(+) 4 & 5, Negative(-) 7 & 8
None
Optional
Included, 6 foot (1.8m)
3.6" x 2.6" x 1.1" (9.2cm x 6.6cm x 2.8cm)
No
(Only available on model M-POE-DUO-S15.5)
www.bitstorm.com
Bad Boy Xtreme
M-POE-DUO-S15.5
5-30 Vdc
15.5 Vdc, 1A max
< 80 mV
Yes – protection circuit
limited to 5A
Yes
up to 90%
approx. 2-4 seconds
Included, 100-240 Vac
North American Style
Yes