Physical Installation
2.1 Site Planning
Follow the requirements specified in this section to prepare a site for the
SA100.
2.1.1 Space Requirements
Leave enough space to remove the magazine tape subsystem from the
front of the cabinet. Also leave enough space to remove the SCSI/STI
adapter assembly from the rear of the cabinet (about 1 meter).
2.1.2 Power Requirements
The subsystem can operate from 100 to 120 Vac at 60 Hz, or from 220 to
240 Vac at 50 Hz.
2.1.3 Environmental Requirements
The SA100 conforms to a modified class A environment (general offices
and workstations). When the SA100 is operating, the temperature should
range from 10 to 40°C with relative humidity of 20 to 80% noncondensing.
When the SA100 is not operating, the temperature should range from –40
to 66°C with relative humidity of 10 to 90%.