Product overview
2.4 Firmware functions
Function
RT (real time)
MRP (Media Redundancy
Protocol)
PROFIenergy
Integrated technology
Integrated closed-loop
control functionality
Security Integrated
Know-how protection
Access protection
Integrity protection
Password provider
18
Description
RT prioritizes PROFINET IO frames over standard
frames. This ensures the required determinism in the
automation technology. In this process the data is
transferred via prioritized Ethernet frames.
The Media Redundancy Protocol enables the configu-
ration of redundant networks. Redundant transmission
links (ring topology) ensure that an alternative commu-
nication path is made available if a transmission link
fails.
Within the PROFINET ring, the H-CPUs assume the
role of the MRP Manager following appropriate project
configuration and all other devices in the ring assume
the role of the MRP clients.
PROFIenergy is a PROFINET-based data interface for
switching off consumers centrally and with full coordi-
nation during pause times regardless of the manufac-
turer or device type. Through this, the process should
only be provided with the energy that is absolutely
required. Most of the energy is saved by the process.
The PROFINET device itself only contributes a few
watts to the savings potential.
PID Compact (continuous PID controller)
•
PID 3Step (step controller for integrating actuators)
•
PID Temp (temperature controller for heating and
•
cooling with two separate actuators)
The know-how protection protects user blocks against
unauthorized access and modifications.
You can use authorization levels to assign separate
rights to different user groups.
The CPUs dispose of integrity protection by default.
Integrity protection identifies possible manipulations of
engineering data on the SIMATIC memory card or
during data transfer between STEP 7 and the CPUs.
Integrity protection also checks the communication
from a SIMATIC HMI system to the CPUs for possible
manipulations of engineering data.
If integrity protection identifies the manipulation of en-
gineering data, the user receives a corresponding mes-
sage.
As an alternative to manual password entry, you can
link a password provider to STEP 7. A password pro-
vider offers the following advantages:
Convenient handling of passwords. STEP 7 auto-
•
matically imports the password for the blocks. This
saves you time.
Optimum block protection because the users do not
•
know the password itself.
Additional information
Function manual PROFINET
(http://support.automation.siemens.c
om/WW/view/en/49948856)
Function manual PID Control
(https://support.industry.siemens.co
m/cs/ww/en/view/108210036)
Redundant System S7-1500R/H
(https://support.industry.siemens.co
m/cs/ww/en/view/109754833) Sys-
tem Manual
CPU 1517H-3 PN (6ES7517-3HP00-0AB0)
Equipment Manual, 11/2019, A5E42011886-AB