Converting the
cooktop from Nat.
Gas to Universal LPG

To change injectors

Changing the nozzles
of the burners on the
cooktop
12
All work involved in installation, setting and adaptation to
a different gas type must be carried out by authorised
personnel from our Service Centre and must comply with
current regulations and the conditions laid down by the
local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Natural Gas
Burner
Hourly Gas
Consumption
(MJ)
Auxiliary
3,60
Semi-rapid
6,50
Rapid
10,80
(60) Double
12,00
flame
(70) Double
flame (inner)
18,00
(70) Double
flame (outer)
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
- Remove the pan supports, burner covers and
diffusers.Fig. 7.
Fig. 7
- Change the nozzles using the spanner provided by our
Service Centre (code 340847, for double and triple flame
burners code 340808), taking special care to ensure that
the nozzle does not fall when it is removed from the
burner or when fitted. Fig. 8.
Universal LPG
Injector
Hourly Gas
mark
Consumption
(MJ)
90
3,50
118
6,00
155
10,00
160
11,00
85
18,00
140
Injector
mark
(mm)
50
67
85
91
46
71