Siemens ED BS Series Информация для использования - Страница 16

Просмотреть онлайн или скачать pdf Информация для использования для Варочная панель Siemens ED BS Series. Siemens ED BS Series 24 страницы. Induction hob with integrated ventilation system

en Cleaning and servicing
5.
Insert the other odour filters or acoustics filters into
the left and right of the appliance.
6.
Insert the grease filter.
Resetting the saturation indicator
Requirement: After the appliance is switched off,
⁠   lights up.
1.
Replace the odour filter. → Page 15
2.
Press and hold
until an audible signal sounds.
a The
display stops lighting up. The saturation indic-
ator for the odour filters is reset.
17.6 Cleaning the grease filters
Grease filters filter the grease from the cooking vapour.
To keep it in good working order, you must clean the
grease filter regularly.
WARNING ‒ Risk of fire!
Fatty deposits in the grease filters may catch fire.
Never operate the appliance without a grease filter.
Clean the grease filters regularly.
Never work with naked flames close to the appli-
ance (e.g. flambéing).
16
1.
ATTENTION!
Falling grease filters may damage the hob below.
Grip below the grease filter with one hand.
Remove the grease filter.
Fat may accumulate in the bottom of the con-
tainer. Hold the grease filter level to prevent
grease from dripping out.
2.
Clean the grease filter.
→ "Cleaning the grease filters manually",
Page 16
→ "Cleaning the grease filter in the dishwasher",
Page 17
3.
If required, remove the odour filters or acoustics fil-
ters and clean the appliance from the inside.
→ "Changing the odour filter or acoustics filter",
Page 15
4.
If any objects get into the appliance, remove these
objects and ensure that the supply to the overflow
container is not blocked.
5.
Wipe out the inside of the appliance with soapy wa-
ter and a dish cloth.
6.
After cleaning, reinsert the dried grease filter.
Cleaning the grease filters manually
1.
Dismantle the grease filter.
2.
Soak the grease filter in hot soapy water.
3.
Use a brush to clean the grease filter.
Do not use aggressive, acidic or alkaline cleaning
products.