Page 80 of User's Guide
Checking the Indicators
The projector is equipped with indicators that alert you to problems with projector operation.
The following tables show what the indicators mean and how to remedy problems that they indicate.
Lamp
indicator
Operation
indicator
Indicator status
Problem and remedy
Standby condition.
Projection starts when the
is pressed.
Cool-down in progress.
After approximately 2 minutes, the projector
switches to the standby condition
(the indicator lights orange).
Projecting in progress.
Warm-up in progress.
After warm-up is complete, projection
will start when a video signal is input.
Internal problem.
Stop using the projector and ask for
projector to be repaired.
Temperature
indicator
Indicator status
button
*1 If an indicator is showing a status which does not appear in the
previous tables, contact your dealer or the nearest address provided at
*1
"International Warranty Conditions" in Safety Instructions/World-Wide
Warranty Terms included in the package.
*2 Contact your dealer for a spare lamp.
lit
flashing
Problem and remedy
This can happen when the power cord was
disconnected from the electrical outlet
before the cool-down period had finished the
last time the projector was turned off.
Wait about 2 minutes. After about 2 minutes,
disconnect the power plug and remove the
lamp. After checking if the lamp is broken,
reinstall it and then and then reinsert the
power plug.
Check that the lamp is properly installed
and the lamp cover is closed.
Or, replace the lamp with a new one.
*2
Lamp will soon need to be replaced.
Replace the lamp as soon as possible.
*2
The appearance of the operation indicator
at this time will vary depending on the status
of the projector.
High temperature inside projector (overheating).
The lamp will turn off automatically and
projection will stop. Wait for about 5 minutes
without operating the projector. After 5 minutes
have elapsed, disconnect the power plug and
then re-insert it.
High-speed cooling in progress.
If the internal temperature rises any higher,
projection will stop.
Check that the air inlet and exhaust vents are clear
and that the indoor temperature is not too high.
Troubleshooting