CABAC 3031 Руководство - Страница 9

Просмотреть онлайн или скачать pdf Руководство для Измерительные приборы CABAC 3031. CABAC 3031 12 страниц. Voltage tester

• L LED lights up for Left rotary field.
• Measurement principle: The instrument detects the pha-
se rising order regarding the user as earth.
Function of this test may not be fully achieved if the
insulation condition/ grounding conditions of user or of
the equipment under test is not good enough.

7.4 Continuity test

Make sure the object under test isn't live.
• Connect both test probes to the object under test. Con-
tinuity LED lights up and buzzer sounds continuously to
indicate continuity

7.5 Torch light

• Pressing the torch light button to turn on the light and
after approx. 10s it will turn itself off

8. Battery Replacement

Remove the probes from any testing point, when
opening the Battery case. Batteries are dead when
the continuity test with both test probes connected
cannot be done anymore. A battery symbol in the
LCD indicates low battery.
Follow the procedure below and replace batteries with
new ones (type IEC LR03 1.5V).
• Unscrew the battery door, e.g. with a coin.
• Pull out the Battery door and replace the batteries. Insert
new batteries according to the engraving on the Battery
door.
• Re-assemble battery door.
• Confirm that the Battery door case is properly locked
prior to measurements.
Battery Replacement
9