Cisco 7200 VXR Series Краткое руководство по эксплуатации - Страница 7
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Беспроводная точка доступа Cisco 7200 VXR Series. Cisco 7200 VXR Series 48 страниц. Preparing for installation
Также для Cisco 7200 VXR Series: Информационный лист (12 страниц), Руководство (14 страниц)
Part
• Port adapter documentation for configuring the interfaces
• T1 channel service unit/data service unit (CSU/DSU) that converts the High-Level Data Link Control (HDLC)
synchronous serial data stream into a T1 data stream with the correct framing and ones density to connect a serial port
to a T1 network. (Some telephone systems require a minimum number of 1 bits per time unit in a data stream, called ones
density.) Several T1 CSU/DSU devices are available as additional equipment, and most provide a V.35, EIA/TIA-449, or
EIA-530 electrical interface.
Prepare for Workbench or Tabletop Installation
For a workbench or tabletop installation, verify the following before installing the router:
• The router is off the floor and has adequate ventilation.
• An adequate chassis ground (earth) connection exists for the router.
• The router has at least 3 inches (7.62 cm) of clearance at the inlet and exhaust vents (sides of router).
• The router has 19 inches (48.3 cm) clearance at the front and rear to allow for field-replaceable unit (FRU) replacement or
installation, or to access cables or equipment.
• Port adapter and power supply filler panels are installed if port adapters and a second power supply are not installed. There
must be no empty slots.
For cable-management bracket installation instructions, see page 8 and 9.
Prepare for Rack-Mount Installation
Make these decisions before you begin the rack-mounting tasks:
• Decide whether or not you want to front- or rear-mount the chassis.
• Decide whether or not you want to attach cable-management brackets.
• Determine the type of rack—four-post or two-post—that you will be using.
Install the CompactFlash Disk, GBICs, and SFPs on the NPE-G1 or NPE-G2
Note
The NPE-G1 and NPE-G2 shis with the CompactFlash Disk, GBICS, and SFPs installed.
If you need to install CompactFlash Disks, GBICs or SFPs into the NPE-G1 or NPE-G2, do so before you rack-mount the router.
If you do not have an NPE-G1 or NPE-G2 in the router, skip to the "Rack-Mount the Router" section on page 10.
Part
• AC power cable-retention clip
7