DigitaLinx DL-1H1V1U-WP-W Руководство пользователя - Страница 16

Просмотреть онлайн или скачать pdf Руководство пользователя для Передатчик DigitaLinx DL-1H1V1U-WP-W. DigitaLinx DL-1H1V1U-WP-W 19 страниц.

DL-1H1V1U-WP-W Owners Manual
RS232 Control and Configuration....continued
Description
Edit RS232 Display On /
Off ASCII String (Up to 64
Characters)
Edit RS232 Display On /
Off HEX Code (Up to 64
Characters)
Query the RS232 Stored
Display On / Off Command
String

USB Mode Configuration

The USB mode on the DL-1H1V1U-WP-W can be defined to operate in a host or client (device) mode.
Use the commands below to adjust the wall plates USB mode
Description
Set USB Mode
Query USB Mode
Reset USB Mode to Factory
Default (Factory default is
host)
16
Command
SET UART_STR {p} 1 {s}
{p} = [poweron, poweroff]
{s} = [xxxx]
xxxx = TV displays ON or OFF
string command (issued by TV
display manufacturer)
SET UART_HEX {p} 1 {h}
{p} = [poweron, poweroff]
{h} = [xx xx]
xx xx = TV displays ON or OFF
string command (issued by TV
display manufacturer)
GET UART_STR {p} 1
{p} = [poweron, poweroff]
Command
SET USB_M {m}
{m} = [host, device]
GET USB_M {m}
{m} = [host, device]
RESET USB_M
Example
Command:
SET UART_STR poweron 1 xxxx<CR><LF>
Return:
SET UART_STR poweron 1 xxxx<CR><LF>
Command:
SET UART_HEX poweron 1 xx xx<CR><LF>
Return:
UART_HEX POWERON 1 xx xx<CR><LF>
Command:
GET UART_STR poweron 1<CR><LF>
Return:
UART_STR poweron 1 xxxx<CR><LF>
Response
Command: SET USB_M device<CR><LF>
Return: USB_M device <CR><LF>
Command: GET USB_M<CR><LF>
Return: USB_M device <CR><LF>
Command: RESET USB_M<CR><LF>
Return: USB_M host <CR><LF>