Sony CCD-TRV338 Camera Руководство - Страница 16

Просмотреть онлайн или скачать pdf Руководство для Видеокамера Sony CCD-TRV338 Camera. Sony CCD-TRV338 Camera 49 страниц. Adjustments
Также для Sony CCD-TRV338 Camera: Ограниченная гарантия (1 страниц)

4. Flange Back Check

Mode
CAMERA
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1: Check that the data of page: 0, address: 10 is "00".
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) ................................................ LCD
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Checking method:
Order Page Address Data
1
2
3
6
40
01
4
6
41
01
5
6
7
0
03
0F
8
1
9
6
21
10
10
11
Processing after completing adjustment:
Order Page Address Data
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
CCD-TRV138/TRV238E/TRV338/TRV438E
Odd: Focused
Even: Unfocused
Procedure
Place the Siemens star 2.0 m
from the front of the lens.
To open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
Shoot the Siemens star with
the zoom TELE end.
Turn on the auto focus.
Check that the lens is
focused. (Note 2)
Shoot the Siemens star with
the zoom WIDE end.
Observe the TV monitor and
check that the lens is
focused.
Procedure
6-14