802.1x protocol.
comply.
Table 1
Firmware Version
PC/PCI cards 4.13
PC/PCI cards 4.16
PC/PCI cards 4.23
PC/PCI cards 4.25 and later
WGB34x/352 8.58
WGB34x/352 8.61 or later
AP34x/35x 11.05 and earlier
AP34x/35x 11.06 and later
AP34x/35x 11.07 and later
AP34x/35x and BR35x 11.21
through 12.01T
Draft standard 8 is the default setting in firmware version 11.05 and earlier, and it might remain in effect
Note
when you upgrade the firmware to version 11.06 or later. Check the setting on the Authenticator
Configuration page in the management system to make sure the best draft standard for your network is
selected.
Use the Authenticator Configuration page in firmware version 11.06 or later to select the draft of the
802.1x protocol the access point or bridge radio should use. Follow these steps to set the draft for your
access point or bridge:
Browse to the Authenticator Configuration page in the access point management system:
Step 1
a.
On the Summary Status page, click Setup.
b.
On the Setup page, click Security.
c.
On the Security Setup page, click Authentication Server.
Use the 802.1x Protocol Version (for EAP authentication) pull-down menu to select the draft of the
Step 2
802.1x protocol the access point or bridge radio should use. Menu options include:
•
•
Release Notes for Cisco Aironet 340 and 350 Series Access Points and 350 Series Bridges Running Firmware Version 12.01T1
OL-3740-01
Table 1
lists firmware versions for Cisco Aironet products and the draft with which they
802.1x Protocol Drafts and Compliant Client Firmware
Draft 7—No radio firmware versions compliant with Draft 7 have LEAP capability, so you
should not need to select this setting.
Draft 8—Select this option if LEAP-enabled client devices that associate with this access point
or bridge use radio firmware versions 4.13, 4.16, or 4.23.
Draft 7
Draft 8
—
x
—
x
—
x
—
—
—
x
—
—
—
x
—
x
—
x
—
x
Limitations and Restrictions
802.1x-2001
—
—
—
x
—
x
—
x
x
x
5