Sony XCU-CG160 Техническое руководство - Страница 15

Просмотреть онлайн или скачать pdf Техническое руководство для Цифровая камера Sony XCU-CG160. Sony XCU-CG160 45 страниц. Digital video camera module

Sony XCU-CG160 Техническое руководство

Image Flip

Flips an image vertically and horizontally.
Reboot the unit to reflect the changes of the setting.
Feature
Parameter
ReverseX
False (0)
True (1)
ReverseY
False (0)
True (1)

Gain

Manual gain

The manual gain can be finely set in 0.1 dB increments.
Although the configurable lower/upper limit values of
the gain are slightly different for each camera, the
configurable values for the GainAnalog parameter are
–1 dB or lower to +27 dB or higher.
The rage of the gain setting that guarantees image
quality is 0 dB to 18 dB.
Feature
Parameter
GainAnalog
–1 or lower to 0 to +27 or
higher

Auto gain (AGC)

By setting auto gain, the gain is automatically adjusted
according to the imaging environment. AGC operates so
that the average level within a detection frame satisfies
the GainAutoLevel setting. The AGC detection frame is
set to the central region by default. The detection frame
can be displayed and the detection area can be changed.
Feature
Parameter
GainAuto
Off (0)
Once (1)
Continuous (2)
GainAutoLevel
0 to 11264 to
16383
GainAutoSpeed
1 to 192 to 256
GainAutoUpperLimit
–1 or lower to
+18 to +27 or
higher
GainAutoLowerLimit
–1 or lower to 0
to +27 or higher
Setting
Off (no flip)
Flip horizontally
Off (no flip)
Flip vertically
Setting
Gain dB unit
Setting
Manual gain
One-push AGC
Continuous AGC
AGC target level
(14 bits)
AGC
convergence
speed
AGC upper limit
AGC lower limit
Feature
GainAutoHighlight
GainAutoAreaWidth
GainAutoAreaHeight
GainAutoAreaOffsetX
GainAutoAreaOffsetY
GainAutoAreaOffsetX
Detection frame area

Area gain

A separate digital gain can be set for up to 16 rectangular
areas.
If multiple rectangular areas are duplicated, the gain
value of the low-numbered area takes priority.
Feature
Parameter
AreaGainEnableAll False (0)
True (1)
AreaGainSelect
0 to 15
AreaGainEnable
False (0)
True (1)
AreaGainWidth
0 to 128 to
Width
AreaGainHeight
0 to 128 to
Height
AreaGainOffsetX
OffsetX to
128 to Width
AreaGainOffsetY
OffsetY to
128 to Height
15
Parameter
Setting
False (0)
AGC detection
frame is hidden
True (1)
AGC detection
frame is
displayed
1 to 50 to 100
Horizontal size of
AGC detection
frame
1 to 50 to 100
Vertical size of
AGC detection
frame
0 to 25 to 99
Horizontal
position of AGC
detection frame
0 to 25 to 99
Vertical position
of AGC detection
frame
GainAutoAreaWidth
Output image
Setting
Gain in all areas set to Off
Gain in all areas set to On
Designates the number of
the area for which to
change parameters.
Gain of area specified by
AreaGainSelect set to Off
Gain of area specified by
AreaGainSelect set to On
Horizontal size of area
Vertical size of area
Horizontal position of
*
area
Vertical position of area
*
*
*