Cisco ASR 9000 Series Руководство по конфигурации - Страница 35

Просмотреть онлайн или скачать pdf Руководство по конфигурации для Сетевое оборудование Cisco ASR 9000 Series. Cisco ASR 9000 Series 46 страниц. Line card
Также для Cisco ASR 9000 Series: Настройка параметров сети (26 страниц), Руководство по конфигурации (50 страниц), Руководство (24 страниц), Настройка (46 страниц), Руководство (44 страниц), Краткое справочное руководство (7 страниц)

Cisco ASR 9000 Series Руководство по конфигурации
Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router
11.
12.
DETAILED STEPS
Command or Action
Step 1
configure
Example:
RP/0/RSP0/CPU0:router# configure
Step 2
controller {t1 | e1} interface-path-id
Example:
RP/0/RSP0/CPU0:router(config)# controller t3
0/1/0/0
Step 3
channel-group channel-group-number
Example:
RP/0/RSP0/CPU0:router(config-t1)# channel-group
1
RP/0/RSP0/CPU0:router(config-t1-channel_group)#
Step 4
bert pattern pattern
Example:
RP/0/RSP0/CPU0:router(config-t1-channel_group)#
bert pattern 2^15
Step 5
bert interval time
Example:
RP/0/RSP0/CPU0:router(config-t1-channel_group)#
bert interval 5
OL-32684-01
bert [t1 | e1] interface-path-id [channel-group channel-group-number] stop
show controllers [t1 | e1] interface-path-id
Cisco ASR 9000 Aggregation Services Router Interface and Hardware Component Configuration Guide
How to Configure Clear Channel T3/E3 Controllers and Channelized T1/E1 Controllers
Purpose
Enters global configuration mode.
Specifies the controller name and instance in the notation
rack/slot/module/port, and enters T1 or E1 controller
configuration mode.
Enters channel group configuration mode for a specific
channel group. Replace channel-group-number with the
number that identifies the channel group on which you want
to configure a BERT.
Enables a specific bit error rate test (BERT) pattern on a T1
line. Valid patterns for all controllers and channel groups
include: 0s, 1s, 2^15, 2^20, 2^20-QRSS, 2^23, and
alt-0-1. Additional valid patterns for T1 and E1 controllers
include: 1in8, 3in24, 55Daly, and 55Octet. Additional
valid patterns for channel groups include: 2^11, 2^9, ds0-1,
ds0-2, ds0-3, and ds0-4.
You must use the bert command in EXEC mode to
Note
start the BER test.
(Optional) Specifies the duration, in minutes, of a bit error
rate test (BERT) pattern on a T1/E1 line. The interval can be
a value from 1 to 14400.
479