Installing PowerCore Devices

How many devices can I stack?

The PowerCore System comes with a 56.4 Watt Internal Hub
Power Supply. The power requirements for each PowerCore™
Powered device can be determined by using the following
configuration guide. For example:
Description
3 PORT FIREWIRE HUB
4 PORT USB HUB
10/100 ETHERNET SWITCH
Therefore, if you had 3 USB Hubs and 1 FireWire Hub
POWERCORE SYSTEM
USB HUB
USB HUB
USB HUB
FIREWIRE HUB
WATTS AVAILABLE
Device Configuration Guide
Volts
Device
PowerCore System
12
NOTE: Volts times Amps equals Watts
CAUTION: CAUTION: If you exceed the power requirements of the
PowerCore™ System as shown above, you will void your warranty.
14
Power Usage (Watts)
18.5 Watts
10.8 Watts
9.9 Watts
56.4 Watts
-10.8 Watts
-10.8 Watts
-10.8 Watts
-18.5 Watts
5.5 Watts
Watts
Amps
Available Watts
4.7
56.4
56.4

Troubleshooting

QUESTION/ISSUE
1
Why does the PowerCore
System emit a loud alarm
when I turn the power on?
2
The Grounding LED is
not on.

Contacting GoldX Products

Internet:
Technical Support:
Sales:
Telephone :
Mailing Address:
ANSWER
The Surge Protection Module is not
installed correctly.
The Surge Protection Module is no
longer functional. Please contact
your reseller for a replacement.
The PowerCore System is connected
into a 2-prong wall power outlet.
Please connect the PowerCore
System directly into a 3-prong
grounded wall power outlet.