Digitrax BXP88 Руководство по эксплуатации - Страница 8

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Датчики безопасности Digitrax BXP88. Digitrax BXP88 16 страниц.

Digitrax BXP88 Руководство по эксплуатации
7.0 Setting BXP88 Board ID and corresponding
Transponding Zone IDs
Setting up your Board ID for your BXP88s should be carefully considered. Each
BXP88 automatically assigns Detection Sections and Transponding Zones based
off the BXP88's Board ID. For example, a BXP88 with a board ID of 001 (factory
default) will report for detection sections 01-08 and transponding zones 00-07.
A BXP88 with a board ID of 002 will report for detection sections 09-16 and
transponding zones 08-17. Each subsequent ID will generate corresponding IDs.
The BXP88 supports board addresses 001-256. When planning your layout it is
important that these section and zone IDs do not overlap. Additional consider-
ations should be taken with incorporating the BXP88s into systems using other
detection or transponding products such as the BDL168 and RX4. Please see the
Digitrax Tech Support Depot for additional information on configuring device
Board IDs.
To set your BXP88 Board ID:
1.
Ensure that your BXP88 is properly connected and powered on.
2.
Press and hold the ID button for approximately 4 seconds until the ID LED
flashes red, then release it. The ID LED will flash alternating red and green.
This let's you know that you are in board address set up mode.
3.
Connect a Digitrax throttle to the BXP88s LocoNet port. (This can only be
done with a Digitrax LocoNet throttle or equivalent software).
4.
Go into SWITCH mode on the throttle. Select the switch number that corre-
sponds to the board address you want to set and issue a closed "c" command
to set the board address. The board address is changed as soon as you issue
the SWITCH command.
5.
Once the Board ID is set the ID LED will go back to solid green.
Please see your specific throttle manual for details on how to issue SWITCH
commands.
8.0 Customizing Your BXP88 – Setting up Option
Switches
A BXP88 with Factory-default settings will generally work on Digitrax DCC
layouts with no modifications, and only the Board ID needs to be set uniquely for
each BXP88 to report allocated Detection section and Transponding Zone num-
bers correctly onto LocoNet.
The implemented option switches and settings you can use to customize your
BXP88 are indicated in Table 1: BXP88 Option Switches. These option switch-
es on your BXP88 are set up using a Digitrax throttle's SWITCH commands.
© 2017 Digitrax, Inc.
— 8 —
www.digitrax.com