Cisco PIX 525 Руководство пользователя - Страница 7

Просмотреть онлайн или скачать pdf Руководство пользователя для Сетевое оборудование Cisco PIX 525. Cisco PIX 525 30 страниц. Security appliance
Также для Cisco PIX 525: Информационный лист (13 страниц)

Cisco PIX 525 Руководство пользователя
Chapter 6
PIX 525
Install the cable for the PIX 525 as shown in
Figure 6-6
Connect the Primary end of the failover cable to the first PIX security appliance; that is, the one you have
Step 3
already configured.
Note
Connect the Secondary end of the failover cable to the standby unit.
Step 4
Connect a power cord to the power connector on the rear panel of each unit, and the other end of each
Step 5
power cord to (preferably separate) power outlets.
If you are using Stateful Failover, use one of the following types of connections, that is appropriate for
Step 6
your system, between the dedicated interfaces on the PIX security appliance:
Category 5 crossover cable directly connecting the primary unit to the secondary unit
100BaseTX half-duplex hub using Straight-through Category 5 cables
100BaseTX full duplex on a dedicated switch or dedicated VLAN of a switch
Note
Do not turn the power on until the units are connected and the primary unit is configured completely.
Caution
Step 7
Power on the primary unit first, then power on the secondary unit. Within a few seconds, the active unit
automatically downloads its configuration to the standby unit.
If the primary unit fails, the secondary unit automatically becomes active.
78-15170-02
PIX 525 Failover Cable Connection
F
A
I
L
O
V
E
R
Primary end
We highly recommend that you use a GE failover link when connecting the PIX 525 with GE
interfaces.
All enabled interfaces must be connected between the active and standby units. Only configure
the active unit. On the PIX 525, the active unit is indicated by the ACT LED on the front panel.
(See
Figure
6-3.)
Figure
6-6.
F
A
I
L
O
V
E
R
Secondary end
Cisco PIX Security Appliance Hardware Installation Guide
Installing Failover