Fimer PVS-60-TL Руководство по быстрой установке - Страница 8

Просмотреть онлайн или скачать pdf Руководство по быстрой установке для Промышленное оборудование Fimer PVS-60-TL. Fimer PVS-60-TL 8 страниц. Solar inverter

Fimer PVS-60-TL Руководство по быстрой установке
AC output voltage range (V
ac min
Maximum AC output current (I
Contributory fault current
Rated output frequency (f
)
r
Output frequency range (f
min
Rated power factor and adjustable range
Total current harmonic distortion
Maximum AC cable cross-section allowed
AC connection type
Output Protection
Anti-islanding protection
Maximum external AC overcurrent protection
Output overvoltage protection - Varistor
Output overvoltage protection - Surge Arrester Type II
Operating Performance
Maximum efficiency (η
)
max
Weighted efficiency (EURO/CEC)
Communication
Integrated communication interface
Communication protocol:
Remote monitoring services
Advanced features
Environmental
Ambient temperature range
Storage temperature
Relative humidity
Sound pressure level, typical
Maximum operating altitude
Classification of the degree of environmental
pollution for the external environment
Environmental category
Physical Specs
Environmental protection degree
Cooling system
Dimensions (H x W x D)
Weight
Mounting system
Overvoltage category according to IEC
62109-1
Safety
Isolation level
Marking
Safety class
1. The output voltage range may vary depending on the specific grid standards of each country.
2. The output frequency range may vary depending on the specific grid standards of each country.
3. In case of failure, it is limited by the external protection device on the AC circuit.
4. Please refer to the document "String inverters – Product manual appendix" available at
5. Only 50Hz
6. Max. installable size 20A
Note. The features that are not specifically mentioned in this data sheet are not included in the product
For more information
please contact your
local FIMER
representative or visit:
fimer.com
PVS-50-TL
...V
)
320...480 Vac
ac max
)
80 A
ac max
92 A
50 / 60 Hz
...f
)
47...53 / 57...63 Hz
max
> 0.995, 0...1 inductive/capacitive with max Smax
< 3.%
95 mm
copper
2
Screw terminal block, cable gland M63
Complying with the local standard (active frequency drift combined with RoCoF techniques)
100 A
Yes
98.4%
98.2% / -
3x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)
Modbus RTU / TCP (Sunspec compliant); Aurora Protocol
Standard level access to Aurora Vision monitoring portal
Integrated Web User Interface; Display (option); Embedded logging and direct transferring of data to
Cloud
-25...+60°C (-13...140°F) with derating over 45°C (113°F)
-40°C...+85°C / -40°F...185°F
4...100% condensing
75 dB(A) @ 1 m
4000 m (13123 ft) with derating above 2000 m / 6561 ft
3
Outdoor
IP 65 (IP54 for cooling section)
Forced air
750 mm x 1100 mm x 257 mm / 29.5" x 43.3" x 10.12"
70 kg / 154 lbs (SX version)
Wall bracket, horizontal support
II (DC input) III (AC output)
Transformerless
CE
(5)
I
FIMER_PVS-50_60-TL-Quick Installation Guide_EN_RevB
We reserve the right to make technical changes or
modify the contents of this document without prior notice.
With regard to purchase orders, the agreed particulars
shall prevail. FIMER does not accept any responsibility
whatsoever for potential errors or possible lack of
information in this document.
(1)
(2)
www.fimer.com
for information on the quick-fit connector brand and model used in the inverter
PVS-60-TL
384...571 Vac
(1)
98.6%
98.4%/-
We reserve all rights in this document and in the
subject matter and illustrations contained therein. Any
reproduction, disclosure to third parties or utilization of
its contents – in whole or in parts – is forbidden without
prior written consent of FIMER. Copyright© 2020 FIMER.
All rights reserved.
23-06-2020
8