AcueLighting Legend 380 Руководство пользователя - Страница 11
Просмотреть онлайн или скачать pdf Руководство пользователя для Осветительное оборудование AcueLighting Legend 380. AcueLighting Legend 380 19 страниц.
serial data link without the use of a DMX optically - isolated splitter may result
in deterioration of the digital DMX signal. The maximum recommended
cable-run distance is 500 meters (1640 ft). The maximum recommended
number of fixtures on a single serial data link is 8 fixtures.
Data/DMX Cabling
To link fixtures together you will need DMX data cables. You should use
data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
In any event, the cable should have the following characteristics:
•2-conductor twisted pair plus a shield
•Maximum capacitance between conductors – 30 pF/ft.
•Maximum capacitance between conductor & shield – 55 pF/ft.
•Maximum resistance of 20 ohms / 1000 ft.
•Nominal impedance 100 – 140 ohms
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR
connector on the other end.
CAUTION:
Do not allow contact between the common and the fixture's
chassis ground. Grounding the common can cause a ground loop, and your
fixture may perform erratically. Test cables with an ohm meter to verify correct
polarity and to make sure the pins are not grounded or shorted to the shield or
each other.
Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the DMX cable to the female connector
(output) on the controller.
Step 2: Connect the female connector of the DMX cable to the first fixture's
11