Table 3: SPECTRUM Events and Alarms and
Trap Varbind Alarm Severity (Value of cerent454AlarmState)
other, administrative, diagnostic, or cleared
minorNonServiceAffecting or minorServiceAffecting
majorNonServiceAffecting, majorServiceAffecting, crucial,
criticalServiceAffecting, or criticalNonServiceAffecting
Trap Variable Data and Alarm Discriminators
All Cisco ONS 15454 (formerly Cerent) traps contain the
in
Table
4. Alarms generated by Cisco ONS 15454 traps are discriminated
by each of the 5 traps shown as an
means that when successive Cisco ONS 15454 traps of the same type are
received by SPECTRUM with the same discriminators as the initial trap, no
new alarms will be generated for those traps. Additionally, alarms will be
cleared when both of the following conditions are met:
•
Trap Varbind Alarm Severity (cerent454AlarmState)
and
• The potentially alarm-clearing trap contains the same
Discriminator (Table
Table 4: Trap Varbind Data for all Cisco ONS Traps
Trap Varbind
cerentNodeTime
cerent454AlarmState
cerent454AlarmObjectType
cerent454AlarmObjectIndex
cerent454AlarmSlotNumber
cerent454AlarmPortNumber
cerent454AlarmLineNumber
cerent454AlarmState
Alarm Discriminator
4) varbinds as the initial trap that set the alarm.
OID
1.3.6.1.4.1.3607.6.10.100.10.20.0
1.3.6.1.4.1.3607.6.10.20.30.20.1.80 No
1.3.6.1.4.1.3607.6.10.20.30.20.1.20 Yes
1.3.6.1.4.1.3607.6.10.20.30.20.1.60 Yes
1.3.6.1.4.1.3607.6.10.20.30.20.1.30 Yes
1.3.6.1.4.1.3607.6.10.20.30.20.1.40 Yes
1.3.6.1.4.1.3607.6.10.20.30.20.1.50 Yes
Cisco ONS 15454
Management Module Guide
Page 11
SPECTRUM