Cisco SCE8000 GBE Процедуры снятия и замены - Страница 3
Просмотреть онлайн или скачать pdf Процедуры снятия и замены для Сервер Cisco SCE8000 GBE. Cisco SCE8000 GBE 36 страниц. 10gbe platform
Также для Cisco SCE8000 GBE: Краткое руководство по эксплуатации (25 страниц), Руководство по конфигурации (18 страниц), Установка (21 страниц)
Chapter 9 Removal and Replacement Procedures
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are
improperly handled, results in complete or intermittent failures. Port adapters and processing modules
consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI)
shielding and connectors are integral components of the carrier. Although the metal carrier helps to
protect the board from ESD, use a preventive antistatic strap during handling.
Following are guidelines for preventing ESD damage:
•
•
•
•
•
•
•
•
For safety, periodically check the resistance value of the antistatic strap. The measurement should be
Caution
between 1 and 10 megohm (Mohm).
Supported Hardware
The Cisco SCE 8000 platform supports the following hardware:
•
•
•
•
OL-26784-02
Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
Connect the equipment end of the strap to an unfinished chassis surface.
When installing a component, use any available ejector levers or captive installation screws to
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental
removal, provide proper grounding for the system, and help to ensure that bus connectors are
properly seated.
When removing a component, use any available ejector levers or captive installation screws to
release the bus connectors from the backplane or midplane.
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or
connectors.
Place a removed component board-side-up on an antistatic surface or in a static shielding container.
If you plan to return the component to the factory, immediately place it in a static shielding
container.
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
Never attempt to remove the printed circuit board from the metal carrier.
One Service Control Module (Cisco SCE 8000-SCM-E), with an optional redundant Service Control
Module (FRU).
One SPA jacket module (Cisco SCE 8000-SIP), with either two or four SPA 10 GBE interface
modules (all FRU).
Up to two optical bypass modules installed in the bottom slot of the chassis.
Hot-swappable fan assembly, redundant AC-input or DC-input power supplies.
Preventing Electrostatic Discharge Damage
Cisco SCE8000 10GBE Installation and Configuration Guide
9-3