1.7 List of parameters of the channel configuration page

Parameter
Par_Contact Type
Type of contact (NO/NC)
PAR_Startup
Channel condition at startup
PAR_Function
Channel function selector (Switch On/Off, On/Off delayed, Blinking, Stairs light)
PAR_On Delay (s)
Delay in seconds selecting function On delayed
PAR_Off Delay (s)
Delay in seconds selecting function Off delayed
PAR_Blink On (s)
On period in seconds selecting function Blinking
PAR_Blink Off (s)
Off period in seconds selecting function Blinking
PAR_Upper Threshold
Upper threshold selecting logical operator THRESHOLD
PAR_Lower Threshold
Lower threshold selecting logical operator THRESHOLD
PAR_Comparison method
Comparison method selecting logical operator THRESHOLD
PAR_Value PORT Locked
Lock value used to lock Channel selecting logical operator PORT
PAR_Stairs Light Time (s)
Light On period in seconds selecting function Stairs Light
PAR_Enable Logic Function
Enable logical block
PAR_Logic Operator
Logical operator when logical block is enabled. Values can be AND, OR, XOR, PORT, THRESHOLD
PAR_Enable Scenes
Enable/Disable scene configuration
PAR_Value Force Out
Forcing status with medium priority
FINDER SpA
Ver. 2018
KNX Actuator 19.6K
Default value
NO
OFF
Switch On/Off
5
5
5
5
0
0
Up
1
30
No
AND
No
OFF