Cisco UCS C220 M4 Служебная записка - Страница 2

Просмотреть онлайн или скачать pdf Служебная записка для Сервер Cisco UCS C220 M4. Cisco UCS C220 M4 10 страниц. For intel xeon v3 series cpus
Также для Cisco UCS C220 M4: Краткое руководство по эксплуатации (29 страниц), Краткое руководство по эксплуатации (29 страниц), Руководство по обновлению (11 страниц)

Cisco UCS C220 M4 Служебная записка
Features Specific to the Cisco UCS C220 M4 NEBS Server

NEBS Compliance

The Cisco UCS C220 M4 NEBS Server has been certified for the following levels of NEBS compliance:

Power Supplies

The Cisco UCS C220 M4 NEBS server can use either AC or DC power supplies.
770 W AC Power Supply
The NEBS server can use one or two 770 W AC power supplies (Cisco PID UCSC-PSU1-770W=).
1050 W DC Power Supply
The NEBS server can use one or two 1050 W, –48 VDC power supplies (Cisco PID
UCSC-PSUV2-1050DC=).

Installation Grounding

The 770 W AC power supplies have internal grounding and so no additional grounding is required when
the supported AC power cords are used.
When using the 1050 W DC power supply, additional grounding of the server chassis to the earth ground
of the rack is available. A single screw hole for use with your grounding lug and grounding wire is
supplied on the chassis rear panel.
You must provide your own screw with lock-washer, grounding lug, and grounding wire. The
Note
recommended lug is Panduit LCD10-14AF-L or equivalent. The grounding point on the chassis is sized
for a single #10-32 screw. A lock-washer is required to secure the lug to the chassis. The grounding lug
must fit a #10-32 screw and 14 AWG wire. The grounding cable that you provide must be 14 AWG
(2 mm), minimum 60° C wire, or as permitted by the local code.
See
Cisco UCS C220 M4 NEBS Server Service Note
2
D R A F T: C i s c o C o n f i d e n t i a l
The DC-power version of the server is certified for NEBS Level 3 compliance.
The AC-power version of the server is certified for NEBS Level 1 compliance.
The server is certified for NEBS Level 1 compliance when using this AC power supply.
These power supplies are hot-swappable with 1+1 redundancy when two power supplies are present.
See
Power Supply Specifications, page
See the
Cisco UCS C220 M4 Server Installation and Service Guide,
replacing a power supply.
The server is certified for NEBS Level 3 compliance when using this DC power supply.
These power supplies are hot-swappable with 1+1 redundancy when two power supplies are present.
See
Power Supply Specifications, page
Figure 1-1
for the location of the grounding lug screw-hole on the chassis rear panel.
5, for information about these power supplies.
5, for information about these power supplies.
Chapter 3, for information about