Digitus Biometrics CodeLock Руководство по установке - Страница 8
Просмотреть онлайн или скачать pdf Руководство по установке для Замки Digitus Biometrics CodeLock. Digitus Biometrics CodeLock 10 страниц.
Connect the lock to 3
-party Access Panel
rd
Orange/White – GND, Ground
Orange – LOCK CTRL. Requires a 12V (24V if a 24V version of the db CodeLock was purchased) control line to unlock the
handle
Green/White – RED LED. Connect to the Red LED output on the 3
-party panel
rd
Blue – V+, Requires a 12VDC Supply
Blue/White – LATCH POS (used to indicate if the lock is open or closed) – Will be pulled to Ground (GND) if the handle is
closed. Will be open circuit if the handle is open. See diagram below
Green – GREEN LED. Connect to the Green LED output on the 3
-party panel
rd
Brown/White – Wiegand DATA 1
Brown – Wiegand DATA 0
db CodeLock
Version 1.3
Digitus Biometrics, Inc. 2017
Page 8 of 10