Sync delay time (Motor2 delay time, reserved late use)
After controller get into special time setting mode, Push and hold on OPN for the sync delay time
setting. Now the red and green LED flash fast alternatively, when reached required time, simply
release OPN button. If no other time need set, simply set DIP1 off, the gate controller will back to
working mode.
Motor Stop time
Push and hold on PED for the motor stop time setting. Now the red and green LED flash fast
alternatively and when gate reached required time, simply release PED button.
PE trig close time
Push and hold on CLS for the PE trig close time setting. Now the red and green LED flash fast
alternatively and when gate reached required time, simply release CLS button.
Reserved
Push and hold OSC reserved late use.
Factory default setting
Timer
Full Open Length
PED Open Length
Auto Close Time
Lock Pulse Time
Motor Stop Time
Sync Delay Time
PE Auto close Time
Reserved
To restore factory setting, turn power off and set DIP1 on, push and hold CLS button then power
on. While hold CLS button, set DIP1 off, release the CLS button. Now controller restored factory
setting from memory.
Attention: First time power up, the motor will run at low speed in close direction
(if DIP6 is on) and hit receiving post. Next open command gate will open at low
speed until to fully opened. The controller will calculate the gate length and
compare it with original gate length. If it is right, the gate will back to normal
operation, otherwise, gate will run at low speed.
6. Inverter settings
When the gate stops, the inverter's display is opening high-speed frequency and flash. This frequency
can be changed by up and down arrows on the inverter. The following form is the inverter's standard
setting for the automatic gate application. Not mentioned function keep as factory setting.
Function
Acceleration time
Deceleration time
Freq. Upper limit
Freq. Lower limit
SP1 Frequency
Start/Stop/Control
Multifunction Input
SP2 Frequency
SP3 Frequency
DIGIWAY PTY LTD
CONTROL BOARD SETTING
F/Setting
Step
10M
0.7mm
5M
0.7mm
30sec.
0.1sec.
0.8ec.
0.1sec.
1.0sec.
0.1sec.
0.5sec.
0.1sec.
2sec
0.1sec
0
0
F
Function Description
1
Acceleration time
2
Deceleration time
6
Max. Frequency
7
Min. Frequency
8
Gate Close High Speed
10
Terminals
20
Reset Terminal Function
26
Gate Open Low Speed
27
Gate Close Low Speed
Setting Method
STD& OPN Button
STD& OPN+PED Button
STD& PED Button
STD& OSC Button
SPE& OPN Button
SPE& PED Button
SPE& CLS Button
SPE& OSC Button
Setting Unit Note
7
Range
No limitation
No limitation
0-6550sec.
0-25sec.
0-25sec.
0-25sec.
0-25sec
0
2.0
Sec.
2.0
Sec.
60
Hz
0
Hz
35
Hz
1
6
20
Hz
15
Hz