DIGIWAY PTY SW50-2S Руководство по эксплуатации - Страница 13
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Открыватель ворот DIGIWAY PTY SW50-2S. DIGIWAY PTY SW50-2S 17 страниц. Dual swing gate motor
STP
Auto Close Time
Set time settings
Turn SET on, red and green LED flashes a little fast alternatively.
Push and hold on OPN for Sync Delay Time
Push and hold on PED for Lock Pulse Time
Push and hold on CLS for PE Trig Close Time
Push and hold on STP for Auto Close Time
Factory setting
Timer
Sync Delay Time
Lock Pulse Time
PE Auto close Time
Auto Close Time
To restore factory setting, turn power off and set DIP1 (SET) on, push and hold
CLS button, then power on. While hold CLS button, set SET1 off and then release
the CLS button. Now controller restored factory setting from memory.
Special settings
To get into Special Setting: Turn power off and set DIP1 (SET) on, push and hold CLS button, then
power on. then release the CLS button. Now controller get into special setting mode
DIP1 On + Special setting.
OPN button---Motor Close Delay Time (Default same to Open Delay Time)
PED button---Spare, CLS button---Spare
OSC button---Spare
Then turn DIP1 off, setting finished
Special setting at the moment only uses OPN bottom to set Close Delay Time. Sometimes Motor
Close Delay Time need to be different to Motor Open Delay Time. Reset Motor Open Delay
Time will reset Motor Close Delay Time, but reset Motor Close Delay Time will not change
Motor Open Delay Tine.
Controller Setting
Auto Close Time
F/Setting
Step
2 sec.
0.1 sec.
2 sec.
0.1 sec.
2 sec.
0.1 sec
30 sec.
0.1 sec.
- 13 -
Setting Method
SET on + OPN Button
SET on +PED Button
SEC on + CLS Button
SET on + PRO Button
Range
0-25 sec.
0-25 sec.
0-25 sec
0-6553 sec