ACCESSING PROGRAMMING MODE PARAMETERS
Press the PTT button or the preprogramed Monitor button to scroll through the features available in
Programming Mode. Press the
Feature
Squelch Level
(SQL-XX)
Time Out Timer
(TOT-XXX)
Scan List 1
(SCANLST1)
Battery Saver
(BS-XXXX)
Battery Type
(BT-XXXX)
20
English
! "
buttons to scroll through the parameters for each feature.
Range
SQL-00, ..., SQL-15
TOT-OFF, TOT-001, ..., TOT-010
1-01-XXX, ...,
1-16-XXX,
XXX denotes channel number.
BS-OFF,
BS-NORM,
BS-ENH
BT-NIMH,
BT-NICD,
BT-ALK
Remarks
Select low level when you need to receive very
weak
signal, and select high level when the
communications distance is near.
This determines the maximum duration (in
minutes) that you can transmit continuously.
Up to 16 members per scan list. First member is
assigned as Priority Channel, if Priority Scan is
started. When scanning is started, only these 16
members will be scanned.
Battery Saver helps to extend your battery life.
When enabled, it turns off radio receiver circuitry
periodically when no activity is detected. BS-
NORM (Normal) turns off the radio less
frequently; select this if you want to save battery,
but expect a Selective Call. BS-ENH (Enhanced)
turns off the receiver for a longer duration; select
this if you want to maximize battery saving and
do not expect to receive any Selective Call.
Selects the type of battery that your radio uses:
NIMH (Nickel Metal Hydride), NICD (Nickel
Cadmium) or ALK (Alkaline).