AC CURRENT
SIMPLE LOGGER
Models L100 & L110

SPECIFICATIONS

MODELS
ELECTRICAL
Number of Channels
Measurement Range
Input
Input Connection
Resolution
Accuracy
Sample Rate
4096/hr max, decreases by 50% each time memory is full
Storage Technique
Data Storage
Output
Indicators
Controls
Power Source
Battery Life
MECHANICAL
Dimensions
Weight
Case Material
Mounting
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
SAFETY
Safety Rating
Double Insulation
4
www.aemc.com
®
Model L100
L100
One
0 to 10,000Arms
(based on probe)
0 to 1Vrms
Recessed safety banana jacks on
8 bit (Max resolution depends on probe)
±1% of Reading + Resolution + probe accuracy
Time Extension Recording
8192 readings
RS-232 via DB9 connector
Red LED double flashes in LOGGING,
single flashes in STANDBY, and is off in OFF mode
One button used to start and stop recording sessions
and to turn the data logger on and off
9V Alkaline battery
Up to one year of recording @ 77°F (25°C)
2.88 x 2 .32 x 1.62" (73 x 59 x 41mm)
5 oz (140g) including battery
Polystyrene UL VO
Base plate mounting holes or Velcro
-4° to 158°F (-20° to 70°C)
-4° to 174°F (-20° to 80°C)
5 to 95% non-condensing
EN 61010, 600V Cat. III
Yes
The Simple Logger
are single channel, low cost data loggers
that require no user setup. They have the
ability to automatically adjust both their
scale range and their sample rate to optimize
the recording session.
The AC current logger measurement range
is 0 to 1Vrms and 0 to 10,000Arms (based
on probe) for Model L100, and 0 to 1Arms
and 0 to 3000Arms (based on probe) for
Model L110.
Both models are compatible with numerous
AEMC current probes.
FEATURES
L110
One
0 to 3000Arms
(based on probe)
0 to 1Arms
3
/
" (19mm) centers
4
APPLICATIONS
(TXR
)
®
pads
Model L110 with 200A AC Current Probe Model MN213
Technical Assistance (800) 343 -1391
®
Models L100 and L110
Supports wide range of current probes
with voltage or current outputs
Two input types to choose from:
Model L100
Use current probes with V
0 to 1Vrms input
0 to 10,000Arms (based on probe)
Model L110
Use current probe with A
0 to 1Arms input
0 to 3000Arms (based on probe)
True RMS measurements
Input via color-coded safety
banana jacks
Select scale via software to
match probe
RS-232 output
One button operation
Accuracy: ±1% of Reading + Resolution
Machine load monitoring
Metering CT re-sizing
Load profiling
Fault finding
And many more
output
AC
output
AC