CONTROLS/ELECTRICAL
The controls in this machine are UL listed and provide for automatic operation and all
required protection of the machine components. Access to the control panel is via the
control cover located on top of the machine.
Air flow is accomplished using internal motorized impellers for process and reactivation
air. The process fan will operate any time the "ON-OFF" switch is in the "ON" position.
The reactivation air fan, heaters, and drive motor will operate when the "HUMIDISTAT"
switch is in "BYPASSED" or via humidity control when the switch is in the "CONTROL
ON" position.
A fractional hp gear motor drives the desiccant rotor.
Self-regulating PTC heater elements provide the "heat source" for reactivation.
MAINTENANCE
This machine is designed for minimal maintenance and years of trouble free service.
Clean the exterior of the machine with a damp cloth and mild soap if necessary.
DO NOT use a garden hose or pressure washer to clean this machine!
Occasionally inspect internal components for loose fasteners or damage from handling.
Inspect the flanged power inlet, connector, and cord for damage.
Check to ensure all access panels are in place and secure.
3