Toshiba 16J2AVSG-E1 Руководство пользователя - Страница 6
Просмотреть онлайн или скачать pdf Руководство пользователя для Кондиционер Toshiba 16J2AVSG-E1. Toshiba 16J2AVSG-E1 20 страниц. Air conditioner (split type)
Также для Toshiba 16J2AVSG-E1: Руководство по установке (20 страниц)
9.2 SILENT OPERATION (Outdoor Unit)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
● Though operating silently, the Heating (or Cooling) capacity is still prioritized
to ensure having sufficient comfort inside the room.
● This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
● Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit's sound level is highly prioritized.
● This setting has a purpose to reduce the maximum sound level of outdoor
unit by 4 dB(A).
Note:
● While activating of Silent operation, inadequate heating (or cooling) capacity
may occur.
Silent Operation Setting
1. Press MENU button for enter menu selection
MENU
During triangle mark blink
2. Enter SILENT set by press MENU button.
triangle mark will stop blink and setting feature will be blink instead.
MENU
3. Select SILENT operation by press TEMP. button.
SILENT#1
SILENT#2
4. Confirm selected feature by press MENU button again.
MENU
When feature had selected will return to menu selection display triangle mark
will blink
5. Leave from menu setting display by select EXIT.
MENU
Blink
°C
can select menu by press TEMP. button.
Blink both triangle and
feature mark Feature not
°C
yet set
°C
°C
None
Blink only triangle
Feature already set
°C
°C
9.3 Hi POWER OPERATION
To automatically control room temperature and airflow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to
select Hi POWER
MENU
2. Confirm selected feature by press MENU button again.
MENU
3. Leave from menu setting display by select EXIT.
9.4 ECO OPERATION
To automatically control room temperature to save energy
(except in DRY and FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to
select ECO
MENU
2. Confirm selected feature by press MENU button again.
MENU
3. Leave from menu setting display by select EXIT.
MENU
Note:
● Cooling operation; the set temperture will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperature will decrease.
Blink both triangle and
feature mark Feature not
°C
yet set
Blink only triangle Feature
already set
°C
°C
ECO
Blink both triangle and
feature mark Feature not
°C
yet set
Blink only triangle Feature
already set
°C
°C
Hi-P