Dimplex BF36E Руководство по установке

Просмотреть онлайн или скачать pdf Руководство по установке для Крытый камин Dimplex BF36E. Dimplex BF36E 10 страниц. Optiflame electric fireplace
Также для Dimplex BF36E: Руководство по эксплуатации (13 страниц)

Dimplex BF36E Руководство по установке
INSTALLATION GUIDE FOR THE
OPTIFLAME ELECTRIC FIREPLACE

LISTINGS AND CODE APPROVALS

The BF series fireplaces have been tested in accordance with the UL 2021and CSA C22.2 No. 46 standards for
fixed and location-dedicated electric room heaters.

MODEL SPECIFICATIONS

Model
Description
Number
BF36E
36"
120/208/240
Economy
BF36ST
36"
120/208/240
Standard
BF36DX
36"
120/208/240
Deluxe
BF42ST
42"
120/208/240
Standard
BF42DX
42"
120/208/240
Deluxe
NOTE: Power ratings shown include the light bulbs and motor (275 watts)
STEP-BY-STEP INSTALLATION
1. Rough in framing opening following the recommended dimensions (Section A: Framing).
2. Allow 8" of service cable for connecting to the junction box on the fireplace. Remove the outer jacket and
strip the individual conductors ½" from the end.
3. Loosen the screw securing junction box cover and remove the cover.
4. Remove knockouts if necessary or use the provided cable clamp.
5. Place unit in position in the opening, level with shims if necessary and attach unit to frame using nailing
flanges provided.
6. Unit is factory wired for 208/240 volt power supply. If 120 volt operation is required, slide the switch and
reconfigure the wiring as covered in section C wiring. Wires L1, L2, N & G are attached to the rear of the
junction box cable clamp for easy access.
7. Wire a dedicated, properly fused circuit with a 20amp rating for the appropriate voltage (120, 208/240).
8. Make wall mounted thermostat and or wall switch connections as outlined in Section C: Wiring.
9. Place all connectors inside the unit and replace the junction box cover, ensuring that the cable clamp grips
only the jacket of service, thermostat and if applicable wall switch lines.
Voltage
Rated Power
Volts
Watts
1650/2340/3025
1650/2340/3025
1650/2340/3025
1650/2340/3025
1650/2340/3025
(Note: Please read all instructions before installing)
Remote
Wall
Refractory
Control
Thermostat
Brick Look
N/A
N/A
Included
Included
Included
Included
Included
Included
Included
Included
7205180100REV01
AMPS
AMPS
120Volt
208Volt
N/A
13.75
11.25
N/A
13.75
11.25
Included
13.75
11.25
N/A
13.75
11.25
Included
13.75
11.25
AMPS
240Volt
12.6
12.6
12.6
12.6
12.6