Dimplex BF39DXP Руководство по эксплуатации - Страница 20

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Крытый камин Dimplex BF39DXP. Dimplex BF39DXP 20 страниц. Fireplace
Также для Dimplex BF39DXP: Практическое руководство пользователя (15 страниц), Руководство пользователя (14 страниц), Руководство пользователя (14 страниц), Руководство по устранению неполадок (2 страниц), Руководство пользователя (14 страниц), Руководство по установке (14 страниц)

Dimplex BF39DXP Руководство по эксплуатации
PROBLEM
heater
Heater is not turning On
Heater is not turning Off
Heater is turning off after a
couple of minutes of operation
Heater emits an odor
Heater fan turns on but heater
lacks heat
Heating element is glowing red
Heater fan runs continuously
Noise
Excessive noise with the heater
on
Grinding or excessive noise with
the heater off
20
CAUSE
Improper operation
Improper Installation of Thermostat/Wall
Controls
Loose wiring
Defective 3-Position Switch
Defective Remote Control Receiver Kit (if
applicable)
Improper operation of unit
Improper operation of Thermostat/Wall
Controls (if applicable)
Defective heater on/off switch
Defective heater assembly
Build up of dirt/dust in heater assembly
Defective Heater Assembly
Normal Operation
Defective heater assembly
Improper operation
Loose wiring
Defective Heater Assembly
Normal Operation
Defective heater element
Defective heater on/off switch
Defective Thermostat/Wall Controls
Dirty blower assembly
Defective Heater motor
Moving flicker rod hitting or rubbing
against internal components
Defective flicker motor
SOLUTION
Refer to Operation Section
Refer to Installation Guide
Trace wiring in unit
Replace 3-Position Switch
Replace Remote Control Receiver Kit
Refer to Operation Section
Refer to Thermostat/Wall Control Operation Guide
Replace heater on/off switch
Replace heater assembly
Ensure that exterior intake louvers and firebox cavity
are free of dirt/dust.
Replace Heater motor (if not running when heat is acti-
vated) or Heater Elements (if motor is running but heat
is not coming out)
Normal operation is when the heater emits an odor
for a brief period after the heater is initially turned on.
The heater is burning off any dust accumulated during
manufacturing or operation.
Replace heater assembly
Refer to Operation Section
Trace wiring in unit
Replace Heater motor (if not running when heat is
activated)
Heater Elements (if motor is running but heat is not
coming out)
Small glowing sections of the element are considered
normal.
If larger glowing sections are causing the heater to trip
the thermal cutout, unplug unit, discontinue use and
replace heater elements
Replace heater on/off switch
Replace Thermostat/Wall Controls
Ensure that exterior intake louvers and firebox cavity
are free of dirt/dust.
Replace heater motor
Ensure rod is straight and mounted properly in the
bracket, spinning freely away from other components.
Replace if necessary.
Replace flicker motor