Warning! Installation by person with electrotechnical
expertise only.
Warnung! Installation nur durch elektrotechnishe
Fachkraft.
Avvertenzal! Fare installare solo da un elettricista
qualificato.
1
Mounting
1.1
Mounting all model
PZ2
5.5 mm
1
2
3
RS-485
I/O
2,5mm
Local wiring rules applies and should be followed. To fulfil the
UL requirements the meter must be installed inside a cabinet or
an enclosure which is UL listed.
NO
B23 UL
INSTALLATION MANUAL
2CMC483004M0002
November 2021
Rev A
Avertissement! Installation uniquement par des
personnes qualifiées en électrotechnique.
¡ Advertencia! La instalación deberá ser realizada
únicamente por electricistas especializados.
RS-485
35 36 37
C
B
(0,25 Nm)
I/O
13 15 16 17 18
13 15
C
C
B23 1xx-xxx
B23 3xx-xxx
(0,25 Nm)
1.2
Connection -B23
L3
L2
L1
N
3 x ≤ 65 A
11
1
4
7
3
6
9
(2,0 Nm)
L3
L2
L1
N
L3
L2
L1
3 x ≤ 65 A
1
4
7
3
6
9
(2,0 Nm)
L3
L2
L1
2
Explanations
Table 1 Button instruction
Button
Function
Down / Up (Short press / Up (long
press
OK (short press / Exit (long
OK
press
Set
SET
Table 2 Symbol instruction
Symbol
Action
Press this button < 1 s (short
press)
Press and hold button > 1 s (long
press)
/
Setting sequence
Screen is flashing
2x
Number of keystrokes
Setting finished
3
Basic settings
3.1
Default settings
Pulse output
Wires
Pulse 1
Wires: 4 Wires
Quantity : Active Energy Import
(3 Phases & Neutral)
Frequency: 100 Imp/kWh
Length: 100 ms
Output: 1
Pulse 2
Quantity : Active Energy Export
Frequency: 100 Imp/kWh
Length: 100 ms
Output: 2
3.2
B23 - Pulse output
1
1 2 3 !
11
T1
0.00
kVV
h
OK
SET
2x
2
1 2 3
12
PULSE
OK
SET
3
13
1 2 3
PULS 1
OK
SET
4
14
1 2 3
QUANT
A
OK
SET
5
15
1 2 3 !
T1
SET
ACt 1
kVV
h
OK
SET
6
16
1 2 3 !
T1
ACt 1
kVV
h
OK
SET
7
17
1 2 3 !
T1
ACt 1
kVV
h
OK
SET
8
1 2 3
18
QUANT
OK
SET
9
19
1 2 3 !
T1
frequen
OK
SET
20
10
1 2 3 !
T1
10
kV
h
OK
SET
3.3
B23/ - Wires
1
3
1 2 3 !
T1
0.00
kVV
h
OK
SET
7x
2
4
1 2 3
ires
OK
SET
3.4
Change / Select values
1. Select a value
Select a value when
the digit blinks.
1 2 3 !
T1
5-5
OK
SET
Example:
Set CT Ratio 100/5
1
1 2 3 !
1 2 3 !
T1
T1
000010
5-5
kV h
OK
SET
OK
SET
7x
2x
3. Change Value
Enter the value when
the digit blinks.
1 2 3 !
T1
10
1 2 3 !
T1
10
kV
h
OK
OK
SET
Example:
Set 10 to 20
1 2 3 !
T1
LENGTh
1
1 2 3 !
T1
10
OK
SET
OK
SET
4x
1 2 3 !
4
Explanations
T1
100
Table 2 Symbol on meter
Symbol
Action
OK
SET
RU symbol
Warning symbol
1 2 3 !
T1
Watthour meter
100
CA 1.0 3W and 4W
ANSI indication
AC symbol
OK
SET
2x
Suitable only for indoor use
Service and maintenance
OBS! Disconnect and make sure that it is absolutely safe to
1 2 3 !
T1
enter the installation before any service and maintenance
100
actions or attempt to clean the meter.
Control on a regular basis that the connections to the meter are
correct with respect to torque, insulation etc. Inspect also the
wires with respect to wear and tear. There is no service or
maintenance required for the meter itself. A meter with mal-
OK
SET
function cannot be repaired and hence it must be replaced.
Recalibration
It should not be necessary to recalibrate the meter during
its lifetime as it is an electronic meter with no moving parts with
electronics and voltage and current sensors that do
not naturally degrade or change with time under specified
1 2 3 !
T1
environmental conditions. If a degradation in the accuracy is
observed the meter has probably been partly damaged (for
OUTPUT
example due to lightning strike or extreme environmental
conditions etc.) and should be exchanged.
Cleaning
SET
If the meter is dirty and need to be cleaned, use lightly moist-
ened cloth with a water based mild detergent. Make sure no
liquid goes into the meter as this could damage the meter and
cause danger.
1 2 3 !
T1
Table 3 Technical data
1 OUT
Nominal voltage
120/208/240/415V AC 3
Voltage range
3x120-240 V AC
(-20% to +15%)
OK
SET
Base current I
5 A
b
Rated current I
-
n
Reference current I
5 A
ref
Maximum current I
65 A
max
Terminal wire area
4/10 AWG Stranded, 10/14 AWG Solid
1 2 3 !
T1
Frequency
50 or 60 Hz ± 5%
1 OUT
Accuracy Class
B (Cl. 1) and Reactive Cl. 2
Active energy
1%
OK
Environmental
SET
Operating
-40 to +70°C
temperature
Storage temperature -40°C to +85°C
Humidity
75% yearly average, 95% on 30 days/year
1 2 3 !
T1
Resistance to water
IP20 on terminal block without protective
1 OUT
and dust
enclosure and IP51 in protective enclosure,
according to IEC 60529.
Mechanical
Class M2 in accordance with the Measuring
environment
Instrument Directive (MID). (2014/32/UE).
OK
SET
Electromagnetic
Class E2 in accordance with the Measuring
environment
Instrument Directive (MID), (2014/32/UE).
Outputs
Current
2 - 100 mA
Voltage
5 - 240 V AC/DC.
5 - 40 V DC. For meters with only 1 output.
Pulse output
Programmable: 1 - 999999 imp/kWh
frequency
1 2 3
Pulse length
Programmable: 10 - 990 ms
3 ires
Terminal wire area
0.5 - 1 mm2
Inputs
Voltage
0 - 240 V AC / DC
OK
SET
OFF
0 - 5 V AC / DC
ON
57 - 240 V AC / 24 - 240 V DC
Min. pulse length
30 ms
Terminal wire area
0.5 - 1 mm2
Standards
1 2 3 !
IEC 62052-11, IEC 62053-21 class 1, IEC 62053-23 class 2, ,
4 ires
OK
SET
Material
Polycarbonate in transparent front glass.
Glass reinforced polycarbonate in bottom case and
upper case. Polycarbonate in terminal cover.
2
1 2 3
100-5
OK
SET
2. Cancel a value
1 2 3 !
T1
5-5
OK
SET
2
1 2 3
000020
OK
SET
3x
3
1 2 3
20
kV
h
OK
SET