Toshiba 20AR21 Руководство по эксплуатации - Страница 13

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для ТЕЛЕВИЗОР Toshiba 20AR21. Toshiba 20AR21 36 страниц. Toshiba color television service manual

20AR21
20AR31
CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
No. Adjusting point
1
CRT CUTOFF
ADJUSTMENT
2
(I
C BUS
CONTROL)
2
SUB-BRIGHT-
NESS
ADJUSMENT
2
(I
C BUS
CONTROL)
3
WHITE BAL-
ANCE SERV-
ICE MODE
ADJ. (I2C BUS
CONTROL)
Maximum
4
beam check
Adjusting procedure/conditions
1. Switch TV to VIDEO mode,BLUE BACK OFF, with
NO VIDEO signal.
2. Press R/C to set Picture Normal condition.
3. Connect the oscilloscope to Red OUT from
IC801.(TP47R)
Range
: 1 V/Div
Sweep
: 5 msec/Div
4. Adjust SCREEN VR ,so that the tip of signal reach
3.5 Vdc + 0.1 Vdc.
1. Call " SUB-BRI" in service mode. (Receive Cross-
hatch pattern with 5 black level windows)
2. Adjust the " SUB BRIGHT " bus data in order that
the line 1, 2 and 3 have the same darkness
wherelse line 4 is slightly brighter than line 1, 2
and 3 and finally line 5 will be the brighter than
line 4.
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between the TP 602
( - ) TP 603 ( + ).
4. Check Beam current should be around (990µA)
5. Set it to service mode and adjust the DRI-G-MH,
& DRI-B-MH data to have a colour temperature
of 11,600°K ( white ).
6. Receive "WHITE" pattern, WITH BURST signal,
and set BRIGHTNESS Y by generator, to ** 10
cd/m2 (MINOLTA CA-100) by reducing LUMINATE
Y signal.
7. Adjust "CUT-R" & "CUT-G" to get 11,600°K. Then
go back NORMAL mode (HIGH BRIGHT**) to
check colour temperature. If out of range, back
to (1).
Note: This adjustment must be done after
warming up the unit for 30 minutes or
longer with a beam current over 500µA.
DRI-R-MH=32
(FIXED)
DRI-G-MH=33
(FIXED)
DRI-B-MH=37
(FIXED)
DRI-R-MH=32
(FIXED)
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between TP603 (+)
and TP602 (–).
(Full Scale: 3 mA Range)
4. Beam current must be within 990 ± 50 µA.
(DC)
1, 2, 3 are in same black level.
# 11,600° K X : 0.273
( MINOLTA COLOUR ANALYZER
CA-100)
*NOTE: Above DATA can be UP/
DOWN by volume key.
20"
* 11,600° K
DRI-GW="DRI-GS"DATA-5
DRI-BW="DRI-BS" DATA-5
12
Waveform and others
3.5Vdc
1 V
0
1 2 3 4 5
Y : 0.280
LOW
HIGH
1.8cd/m
2
115cd/m
2