MSI MSI-8000HD Руководство по эксплуатации - Страница 34
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Монитор MSI MSI-8000HD. MSI MSI-8000HD 48 страниц. Rf remote display
Access the Service Counters
1)
Program a User Function key to
be TEST (see function key setup).
For this example,
programmed as TEST.
2)
Press
F1- TEST
3)
Within 2 seconds of pressing the
F1– TEST
key, press
(must be F1 regardless of which key is
programmed as TEST).
The test will sequence through steps 4
to 7 automatically unless you stop it by
pressing
F2
immediately. Then using
F1
and
F2
each parameter can be
observed statically.
4)
The display flashes "LFCnt" (for
Lift Counter) followed by the
number of times the weight has
exceeded 25% of capacity.
5)
Next, the display flashes "OLCnt"
(for Overload Counter) followed
by the number of times the
weight has exceeded capacity.
6)
Next,the display flashes the C-
Cal value.
7)
The Dynalink / Scale returns to
standard weighing mode. If you
interrupted the auto sequence,
press
ZERO
link mode.
Only a MSI factory representative can reset the service counters, as these are an
important safety warning feature. Depending on the circumstances, a thorough load
train inspection is necessary to ensure product safety.
Reference MSI's "Crane Scale Safety and Periodic Maintenance Manual" for proper
loading techniques to improve the safety and longevity of your Crane Scale or Dyna-
Link. This publication is available at www.msiscales.com and is included in the CD
shipped with your MSI-8000HD.
30
MSI-8000HD Operator's Manual
F1
is
.
F1
again
to return to tension
Figure 5-8. Access the Service Counters
Fx
ENTER/SELECT
Number of Lifts above 25% of Capacity
blinking
Number of Lifts that exceeded Capacity
blinking
Return to standard weight display
Start of Test Sequence
All segments on
example value
example value
example C-Cal value