Toshiba TLP711E Руководство по техническому обучению - Страница 17

Просмотреть онлайн или скачать pdf Руководство по техническому обучению для Проектор Toshiba TLP711E. Toshiba TLP711E 31 страница. 3 lcd data projector
Также для Toshiba TLP711E: Руководство по эксплуатации (30 страниц)

Toshiba TLP711E Руководство по техническому обучению

4-10. Various Display Modes

4-10.
Various Display Modes
In this system, various LED display patterns are provided
in relation to the display modes shown in Table 4-8-1.
Operation processes from the status of AC cord plugged
to that of power on and power off will be given below.
(1)
Data of the non-volatile memory are checked when
the AC cord is plugged, and all the LEDs are turned
on in red in the initial use. In second or later use, all
the LEDs are turned on in green and the unit enters
the standby status.
(2)
In the standby status, only the ON/STANDBY LED
is turned on in orange, and the main power is off
and the lamp power is also off.
(3)
When the power is on by pressing the ON/
STANDBY key, the unit enters a normal status in
passing through following processes.
1) The main power is on, and ON/STANDBY LED
turns on in green.
2) The fan power is on, and the fan starts to rotate.
3) The lamp power is on, and LAMP LED blinks
in green for about 3s.
4) With the lamp turned on, LAMP LED turns on
in green and the unit enters the normal status.
(4)
If the lamp does not turn on, ON/STANDBY LED
turns on in orange, and the LAMP LED blinks in
green for about 1 min. and then the unit returns to
the standby status.
(5)
In the normal status, ON/STANDBY LED and the
LAMP LED are turned on in green, and the main
power and the lamp power are turned on.
(6)
When the power is turned off by pressing the ON/
STANDBY key, the unit enters the standby status in
passing through following processes.
1) After the lamp power is turned off, the main
power turns off and then ON/STANDBY LED
turns on in orange.
2) The LAMP LED blinks in green for about 1
min. For this period the lamp can not be turned
on again by the ON/STANDBY key.
3) When the LAMP LED stops blinking in green,
only the ON/STANDBY LED turns on in
orange. After this, the lamp can be turned on
again by the ON/STANDBY key.
(7)
Moreover, the fan works for about 2 min. to lower
temperature of the unit. Then, the fan also stops and
returns to the standby status by turning off the fan
power supply.
(8)
If an error occurs due to some causes, the ON/
STANDBY LED turns on in red, and the error
information is kept in the display status of the
LAMP and TEMP LEDs. When the error is
detected, the unit enters the standby status after
cooling down process for about 2 min. In this case,
if the error status continues, the error display is also
kept and any key entry is not accepted.
4-11.
4-11. Applicable Signal
Applicable Signal
Various kinds of signals are used as the applicable signals in
the preset mode (standard value) as shown in Table 4-11-1.
For the signals not fit to the preset modes, other mode is
provided.
4-6