Installation of Switch Panel
WARNING: The Switch Panel should not be installed in a toilet or
washroom.
The backing box (standard B.S. double gang as shown in Fig. 5) should
be rebated into a suitable wall. The box should be fi tted so that the switch
panel will be fl ush with the wall. Suitable wall conduit should be used where
applicable to carry the cable between the heater and the switch panel.
75

Installation of Heater

The Installation of this product must only be carried out by a prescribed
competent person in accordance with Building Regulations and the current
IEE Wiring Regulations for electrical equipment.
This heater can either be installed into a suspended or plasterboard ceiling.
First it is necessary to ensure that 200mm of suffi cient space exists above
the ceiling for the Installation of this product (see Fig. 1 and Fig. 7).
This product is designed to be suspended by threaded rod or wires/chains.
Always ensure this unit is adequately supported when installed.
Mounting of Heater
Installation in a plasterboard (or similar) Ceiling
A hole (610x610mm) as indicated in Fig. 1 and Fig. 6 must be cut into the ceiling.
It may be necessary to fi x an internal supporting frame around the newly cut
aperture in a plasterboard ceiling.
see Fig. 11
To mount the unit into the ceiling void, use lengths of threaded bar or hooks
(not supplied) screwed into the M8 threaded inserts located in the top side
of the heater (see Fig. 1 for dimensions). Adjust the height of the heater so
the air inlet/outlet panel is positioned inside the grille frame and no more than
70mm above the installed height of the egg crate grille which allows access
for future maintenance. The unit should also be positioned inside the grille
400
Access Panel
265
Doorway
Fig. 7
48
2 3
1
85
120
145
opening to achieve optimum air-fl ow
effect, as shown in Fig. 8.
Installation in a Bulk Head
(over doorway)
A hole (576x265mm) as indicated in
Fig. 7, must be cut into the ceiling part
of the bulk head. Drop rods should
be used to mount the appliance in
such a position, as to have the base
flush with the ceiling. An access
panel should also be provided on the
front of the bulkhead. This provides
access to the top of the appliance
and the access plate for wiring the
appliance.
70mm max.
70
max.
4 4 0mm min.
min.
Installation in a Suspended Ceiling
A standard 600 x 600mm ceiling tile needs to be removed as close to
the fi nal position of the product as possible.
There are four options for mounting the appliance in a suspended ceiling:
1.
Use suitable length M8 threaded bar and screw into the threaded inserts
provided on the top of the heater - see Fig. 1 for dimensions.
2.
Bend up the 'Wire Hooks' as shown in Fig. 9 and use suitable suspended
Fig. 5
ceiling wire to suspend the heater. (Note the appliance should be mounted
as to prevent swaying of the product during operation).
3.
Without Egg Crate Grill: Use the rail brackets provided. Bend the rail
brackets as shown in Fig. 10. The appliance should be placed directly
onto the suspended ceiling structure in the desired location. Using the
screws provided screw the rail brackets onto the heater (Top Holes -
see Fig. 9) so that it grips the suspended frame (see Fig. 10) Close the
remaining space around the heater with a cut ceiling tile.
Fig. 6
4.
With Egg Crate Grill: Use the rail brackets and ceiling tile provided.
Pick a location to mount the heater. Remove the existing ceiling tile
and replace with metal tile supplied. The appliance should be placed
directly onto the metal ceiling tile. Using the screws provided screw the
rail brackets onto the heater (Bottom Holes - see Fig. 9) so that it grips
the suspended frame (see Fig. 10).
Note: Please ensure that the ceiling structure can withstand the weight of
the appliance.
Operation of Switch Panel
Switch on electrical supply (MAINS IN) to the Switch Panel.
Switching the switch marked 'I' (see '1' in Fig. 5) energises the fan and
switches on the electrical supply to the heater.
The heat selection switches allow heat settings to be chosen as shown
below:
Settings - I
The desired setting can be obtained through switch selection.
Fan Only
I +
1
/
Heat
2
I +
Full Heat
200mm
200
min.
min.
Fig. 8
TOP HOLES : WITHOUT TILE
BOTTOM HOLES : WITH TILE
Fig. 9
1
2
Fig. 10